OPERATION

PREPARATION FOR START-UP . . . . . . . . . . . . . . . . . . . . 21

Checking Rotation . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Coupling Pump and Driver . . . . . . . . . . . . . . . . . . . . . . . . 21
Lubricating Bearings . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Shaft Sealing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Priming Pump . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Start-up Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . 23

STARTING PUMP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24

General Considerations. . . . . . . . . . . . . . . . . . . . . . . . . . 24
Operational Checks. . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Operating at Reduced Capacity . . . . . . . . . . . . . . . . . . . . . 25
Operating Under Freezing Conditions . . . . . . . . . . . . . . . . . . 25

SHUTDOWN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
FINAL ALIGNMENT . . . . . . . . . . . . . . . . . . . . . . . . . . . 25

PREPARATION FOR START-UP

!

When installation in a potentially explosive
environment, ensure that the motor is properly
certified.

CHECKING ROTATION

$

CAUTION

Serious damage may result if pump is run in the
wrong rotation.

1.

Lock out power to driver.

s

!

WARNING

Lock out driver power to prevent accidental start-up
and physical injury.

2.

Make sure coupling hubs are securely fastened
to shafts.

s

!

WARNING

Do NOT jog a coupled pump.

NOTE: Pump is shipped with coupling spacer
removed.

3.

Unlock driver power.

4.

Make sure everyone is clear. Jog driver just long enough to
determine direction of rotation. Rotation must correspond
to arrow on bearing frame.

5.

Lock out power to driver.

COUPLING PUMP AND DRIVER

s

!

WARNING

Lock out driver power to prevent accidental rotation
and physical injury.

!

The coupling used in an ATEX classified environ-
ment must be properly certified.

1.

Install and lubricate coupling per manufacturer’s
instructions.

!

The coupling guard used in an ATEX classified
environment must be constructed from a non-
sparking material.

2.

Install coupling guard. Refer to coupling guard
installation instructions in Appendix I.

s

!

WARNING

Never operate a pump without coupling guard properly
installed. Refer to
Appendix I for coupling guard
installation instructions. Personal injury will occur if
pump is run without coupling guard.