beautypg.com

General precautions – Goulds Pumps 3910 11th ed. - IOM User Manual

Page 10

background image

S-6

General Precautions

WARNING

Ensure pump is isolated from system and pressure is relieved before

disassembling pump, removing plugs, opening vent or drain valves, or

disconnecting piping.

WARNING

Shutdown, Disassembly, and Reassembly:
Pump components can be heavy. Proper methods of lifting must be employed to

avoid physical injury and/or equipment damage. Steel toed shoes must be worn at

all times.

WARNING

The pump may handle hazardous and/or toxic fluids. Observe proper

decontamination procedures. Proper personal protective equipment should be

worn. Precautions must be taken to prevent physical injury. Pumpage must be

handled and disposed of in conformance with applicable environmental

regulations.

WARNING

Operator must be aware of pumpage and safety precautions to prevent physical

injury.

WARNING

Lock out driver power to prevent accidental startup and physical injury.

CAUTION

Allow all system and pump components to cool before handling them to prevent

physical injury.

CAUTION

If pump is a Model NM3171, NM3196, 3198, 3298, V3298, SP3298, 4150, 4550,

or 3107, there may be a risk of static electric discharge from plastic parts that are

not properly grounded. If pumped fluid is non-conductive, pump should be

drained and flushed with a conductive fluid under conditions that will not allow

for a spark to be released to the atmosphere.

WARNING

Never apply heat to remove an impeller. The use of heat may cause an explosion

due to trapped fluid, resulting in severe physical injury and property damage.

CAUTION

Wear heavy work gloves when handling impellers as sharp edges may cause

physical injury.

CAUTION

Wear insulated gloves when using a bearing heater. Bearings will get hot and can

cause physical injury.