beautypg.com

Goulds Pumps 3420 - IOM User Manual

Page 21

background image

3.

Carefully lower the baseplate onto the foundation
bolts.

4.

Level the baseplate to within .125 in. (3.2 mm) over
the length of the baseplate and to within .088 in. (1.5
mm) over the width of the baseplate by adjusting the
wedges. If the baseplate has vertical leveling screws,
use the screws to level the base.

5.

Hand tighten the foundation bolts.

3420 IOM 08/09

17

Fig. 7

3