Guidelines for i-ALERT
™
Condition Monitor disposal
Precautions
WARNING:
• Never heat the condition monitor to temperatures in excess of 300°F (149°C). Heating to these
temperatures could result in death or serious injury.
• Never dispose of the condition monitor in a fire. This could result in death or serious injury.
Guidelines
The battery contained in the condition monitor does not contain enough lithium to qualify as reactive
hazardous waste. Use these guidelines when disposing of the condition monitor.
• The condition monitor is safe for disposal in the normal municipal waste stream.
• Adhere to local laws when you dispose of the condition monitor.
Disassemble the C-face adapter
NOTICE: You must properly support the motor with a clean, uncorroded eye bolt or a strap under both
end bells. Failure to do so may result in equipment damage.
1. Loosen the motor-mounting bolts and remove the motor.
This table shows the number of motor-mounting bolts.
Table 11: Required number of motor-mounting bolts
Pump frame
Motor frame
Number of bolts
STi
All
4
MTi
143-286
4
324-365
8
2. Loosen the bolts attached to the bearing-frame flange and remove the C-face adapter from the
bearing frame.
Maintenance
Model 3198 i-FRAME Installation, Operation, and Maintenance Manual