Piping checklists

General piping checklist

Precautions

CAUTION:

• Never draw piping into place by using force at the flanged connections of the pump. This can impose

dangerous strains on the unit and cause misalignment between the pump and driver. Pipe strain
adversely affects the operation of the pump, which results in physical injury and damage to the
equipment.

• Vary the capacity with the regulating valve in the discharge line. Never throttle the flow from the

suction side. This action can result in decreased performance, unexpected heat generation, and
equipment damage.

Piping guidelines

Guidelines for piping are given in the Hydraulic Institute Standards available from the Hydraulic Institute
at 9 Sylvan Way, Parsippany, NJ 07054-3802. You must review this document before you install the pump.

Checklist

Check

Explanation/comment

Checked

Check that all piping is

supported independently of, and

lined up naturally with, the pump

flange.

This helps to prevent:
• Strain on the pump
• Misalignment between the pump and the drive unit
• Wear on the pump bearings and the coupling
• Wear on the pump bearings, seal, and shafting

Keep the piping as short as

possible.

This helps to minimize friction losses.

Check that only necessary fittings

are used.

This helps to minimize friction losses.

Do not connect the piping to the

pump until:
• The grout for the baseplate or

sub-base becomes hard.

• The hold-down bolts for the

pump and the driver are
tightened.

Make sure that all the piping

joints and fittings are airtight.

This prevents air from entering the piping system or

leaks that occur during operation.

If the pump handles corrosive

fluids, make sure that the piping

allows you to flush out the liquid

before you remove the pump.

If the pump handles liquids at

elevated temperatures, make sure

that the expansion loops and

joints are properly installed.

This helps to prevent misalignment due to linear

expansion of the piping.

Installation

34

Model 3198 i-FRAME Installation, Operation, and Maintenance Manual