Quick reference guide – Myron L CTCIITD User Manual

Page 4

background image

CTCII

CHEMICAL TREATMENT CONTROLLER

(COOLING TOWER CONTROLLER)

QUICK REFERENCE GUIDE!

If you read nothing else in this

manual please read this

Quick Reference Guide.

PLEASE READ and COMPREHEND ALL

WARNINGS, CAUTIONS and ADVISEMENTS

CONTAINED WITHIN THIS MANUAL.

Failure to comply is beyond the responsibility of the

Myron L Company.

WARNING: ALL CONTROLLERS ARE FACTORY SET TO

OPERATE ON 115 VAC. BEFORE APPLYING POWER ENSURE

THE INPUT POWER “115/230 VAC” SELECTION IS CORRECT

FOR YOUR REQUIREMENTS. FAILURE TO DO SO IS BEYOND

THE RESPONSIBILITY OF THE MYRON L COMPANY. See

section II.D.1. and figure II.E.1.

WARNING: ENSURE POWER IS OFF WHILE INSTALLING

ELECTRICAL EQUIPMENT. IF MONITOR/CONTROLLER

IS INSTALLED, ENSURE THE POWER IS OFF BEFORE

SERVICING. FAILURE TO DO SO COULD CAUSE DAMAGE

TO THE INSTRUMENT, AND COULD BE HARMFUL OR FATAL

TO PERSONNEL. ONLY QUALIFIED PERSONNEL SHOULD

INSTALL OR SERVICE ELECTRICAL EQUIPMENT.

CAUTIONS: Before installation, ensure you have the correct

model (with options), AND it is scaled for your application.

See sections I.A. & I.B.

Do you have the correct sensor? See section I.E.

Mounting requirements. What is needed? See section II.B.

The following will give the installer and user a quick

overview. See the sections listed for details.

REMOVING FRONT PANEL

1. Using a Phillips Head screwdriver remove the four (4)

screws on the clear cover.

2. Remove clear cover.

3. The front panel is held in place with hook & loop strips

on each side. By carefully lifting at the slot on the top,

the front panel will pull toward you. Do not pull more than

about 8 inches/20CM.

DO NOT pull on control knob(s).

4. Rotate the front panel down so that the back side is

facing you. The Main Circuit Board is mounted to the

back of the front panel.

REASSEMBLY

1. Carefully reinstall the front panel.

2. Reinstall the clear cover.

3. Reinstall the four (4) screws and tighten.

4. If desired, install corner covers.

5. To operate, turn power ON.

INTRODUCTION - Section I.

This section covers the specifications of your new CTCII

Chemical Treatment Controller including sensor information.

INSTALLATION - Section II.

This section covers how to install your new CTCII Chemical

Treatment Controller; mechanically and electrically.

OPTIONS & ACCESSORIES - Section III.

This section covers the specifications, installation, set up, and

operation of each option.

OPERATING PROCEDURES - Section IV.

This section covers a brief description of different models and

their features; how they work, and how to set them up for your

particular use.

QUICK CHECK-OUT PROCEDURE -

See Section IV.B.1.

It is assumed that the Controller power is ON, that it is connected

to an appropriate sensor, and that the sensor is immersed in water

within the range that the Controller will be required to operate, and

the clear lid is removed from the Controller.

1. Rotate the large Set Point Control knob on the front

panel through its entire range.

2. Verify that the set point indicator light changes from RED

to GREEN and visa versa.

3. Verify that the relay clicks, and controls the bleed valve

and/or chemical feed pump.

4. Adjust the set point control to the desired set point value.

5. Re-install clear cover.

HYSTERESIS (DEAD BAND) ADJUSTMENT -

See Section IV.B.3.

PRIMARY COMPONENT IDENTIFICATION -

Section V.A.

Review the figure on the following page to familiarize yourself with

the Main circuit board assembly. The diagram shows the Limit

Timer and the optional 4-20 mA Output module installed.

QUICK CALIBRATION - Section V.B.
WARNING: When performing calibration procedures, the

technician must take extreme care to avoid contacting the

circuitry other than the CALibration control. Failure to do so

could result in damage to the equipment, property and/or

personal injury.