9. Technical Data
9.1. Environmental
Operational ambient temperature range
Open Drives:
-10 … 50°C (frost and condensation free)
Enclosed Drives:
-10 ... 40°C (frost and condensation free)
Storage ambient temperature range:
-40 … 60°C
Maximum altitude:
2000m. Derate above 1000m : 1% / 100m
Maximum humidity:
95%, non-condensing
NOTE
For UL compliance: the average ambient temperature over a 24 hour period for 200-240V, 2.2kW and 3HP drives is 45°C.
9.2. Rating Tables
110 - 115 Volt (+ / - 10%) 1 Phase Input, 3 Phase 230V Output
Frame
size
Power
rating
Nominal
Fuse
Supply
Nominal
Motor
Maximum
Recommended
Input
Or
Cable
Output
Cable
Motor
Brake
Current
MCB (Type B)
Size
Current
Size
Cable
Resistance
[kW]
[A]
Non UL
UL
[mm2]
AWG / kcmil
[A]
[mm2]
AWG / kcmil
Length [m]
Ω
1
0.37
11.0
16
15
2.5
14
2.3
1.5
14
50
-
1
0.75
19.0
25
25
4
10
4.3
1.5
14
50
-
2
1.1
25.0
32
35
6
8
5.8
1.5
14
100
50
200 - 240 Volt (+ / - 10%) 1 Phase Input, 3 Phase Output
Frame
size
Power
rating
Nominal
Fuse
Supply
Nominal
Motor
Maximum
Recommended
Input
Or
Cable
Output
Cable
Motor
Brake
Current
MCB (Type B)
Size
Current
Size
Cable
Resistance
[kW]
[A]
Non UL
UL
[mm2]
AWG / kcmil
[A]
[mm2]
AWG / kcmil
Length [m]
Ω
1
0.37
5.0
10
10
1.5
14
2.3
1.5
14
50
-
1
0.75
8.5
10
10
1.5
14
4.3
1.5
14
50
-
1
1.5
13.9
16
20
2.5
12
7
1.5
14
50
-
2
1.5
13.9
16
20
2.5
12
7
1.5
14
100
100
2
2.2
19.5
25
25
4
10
10.5
1.5
14
100
50
200 - 240 Volt (+ / - 10%) 3 Phase Input, 3 Phase Output
Frame
size
Power
rating
Nominal
Fuse
Supply
Nominal
Motor
Maximum
Recommended
Input
Or
Cable
Output
Cable
Motor
Brake
Current
MCB (Type B)
Size
Current
Size
Cable
Resistance
[kW]
[A]
Non UL
UL
[mm2] AWG / kcmil
[A]
[mm2] AWG / kcmil
Length [m]
Ω
1
0.37
3.0
6
6
1.5
14
2.3
1.5
14
50
-
1
0.75
4.5
6
6
1.5
14
4.3
1.5
14
50
-
1
1.5
7.3
10
10
1.5
14
7
1.5
14
50
-
2
1.5
7.3
10
10
1.5
14
7
1.5
14
100
100
2
2.2
11.0
16
15
2.5
12
10.5
1.5
14
100
50
3
4
18.8
20
20
4
10
18
2.5
10
100
50
380 - 480 Volt (+ / - 10%) 3 Phase Input, 3 Phase Output
Frame
size
Power
rating
Nominal
Fuse
Supply
Nominal
Motor
Maximum
Recommended
Input
Or
Cable
Output
Cable
Motor
Brake
Current
MCB (Type B)
Size
Current
Size
Cable
Resistance
[kW]
[A]
Non UL
UL
[mm2]
AWG / kcmil
[A]
[mm2]
AWG / kcmil
Length [m]
Ω
1
0.75
2.4
6
6
1.5
14
2.2
1.5
14
25
-
1
1.5
4.3
6
10
1.5
14
4.1
1.5
14
25
-
2
1.5
4.3
6
10
1.5
14
4.1
1.5
14
50
200
2
2.2
6.1
10
10
1.5
14
5.8
1.5
14
50
200
2
4
9.8
16
15
2.5
12
9.5
1.5
14
50
100
3
5.5
14.6
20
20
4
10
14
1.5
12
100
100
3
7.5
18.1
25
25
4
10
18
2.5
10
100
50
3
11
24.7
32
35
10
8
24
4
10
100
50
Note
: For UL compliance, Motor Cable to be 75°C Copper, fuse current ratings in brackets (), UL Class T must be used.