Ip20 easy start-up guide – Beijer Electronics Industrial Inverter E2 User Manual
Page 2

2
AC Supply Voltage
(50 / 60Hz)
L1 L2 L3
Earth L N
Fuses or MCB
Supply Voltage :
-
110-115, 200-240, 400-480 +/- 10%
-
1 or 3 Phase
-
Check the drive rating information on page 28
Fuses or MCB, Cable Sizes :
-
Check the drive rating information on page 28
-
Recommended cable sizes shown on page 28
-
Keypad operation can be found on page 17
Control Terminals :
Based on the default, out of box settings –
-
Connect a Start / Stop switch between terminals 1 & 2
-
Close the switch to start
-
Open the switch to stop
-
Connect a potentiometer (5kΩ minimum) terminals 5, 6 &
7 to vary the speed from minimum (0Hz) to maximum (50
/ 60Hz)
-
Motor Cable Sizes
-
Check the rating information on page 28
-
For EMC compliance, use a shielded type cable
Motor Connections
-
Check for Star or Delta connection according to the motor
voltage rating (See page 13)
Motor Nameplate Details
-
Enter the motor rated voltage in P-07
-
Enter the motor rated current in P-08
-
Enter the motor rated frequency in P-09
IP20 Easy Start-Up Guide
RJ45
Connector
Mechanical Mounting
-
Information can be found on page 10