4 pin description of x1 terminal block, 5 technical data of the connection terminals, Pin description of x1 terminal block – Beijer Electronics M70 EN User Manual
Page 35: Technical data of the connection terminals, 4 pin description of x1 ter, Minal block

Connection Box
Beijer Electronics, MAEN843A
35
14.4 Pin Description of X1 Terminal Block
For connection details such as Ethernet and RS232C wiring diagrams, see chap-
ter
.
14.5 Technical Data of the Connection
Terminals
The following technical data apply to the X1 and X3 connector terminal blocks
already available in the connection box:
PHOENIX Order Data
Pin 1
24 V DC
Pin 6
Emergency stop, circuit 2
Pin 2
GND_IN
Pin 7
Enabling switch, circuit 1, pos.
Pin 3
Emergency stop, circuit 1
Pin 8
Enabling switch, circuit 1, neg.
Pin 4
Emergency stop, circuit 1
Pin 9
Enabling switch, circuit 2, pos.
Pin 5
Emergency stop, circuit 2
Pin 10 Enabling switch, circuit 2, neg.
Parameter
Connection box
Connection capacity
rigid
flexible
wire gages
0.14-1.5 mm²
0.14-1.5 mm²
28-16 AWG
Connection capacity flexible with wire end ferrules
without plastic sleeve
with plastic sleeve
0.25-1.5 mm²
0.25-0.5 mm²
Grid dimension
3.81
Insulation length
7 mm²
Tightening torque
0.22-0.25 Nm
Gateway terminal block
PHOENIX type
Part no.
X1
MCVR 1.5/6-ST-3.81
1827169
X3
MCVR 1.5/7-ST-3.81
1827172
X4, X4B
MCVR 1.5/10-ST-3.81
1827208