Environmental requirements, 6 environmental requirements – Acer 365 User Manual
Page 37

System Introduction
1-27
1.6 Environmental
Requirements
Table 1- 37
Environmental Requirements
Item
Specification
Temperature
Operating (
)
+5~ +35
Non-operating(
)
-20 ~ +60
Humidity
Operating (non-condensing)
20% ~ 85%
Non-operating (non-condensing)
20% ~ 90%
Operating Vibration (unpacked)
Operating
5 - 25.6Hz, 0.38mm; 25.6 - 250Hz, 0.5G
Sweep rate
0.5 octave / minute
Number of test cycles
2 / axis (X,Y,Z)
Non-operating Vibration (unpacked)
Non-operating
5 - 27.1Hz, 0.6G; 27.1 - 50Hz, 0.41mm; 50-500Hz, 2G
Sweep rate
0.5 octave / minute
Number of text cycles
4 / axis (X,Y,Z)
Non-operating Vibration (packed)
Non-operating
5 - 62.6Hz, 0.51mm; 62.6-500Hz, 4G
Sweep rate
0.5 octave / minute
Number of text cycles
4 / axis (X,Y,Z)
Shock
Non-operating (unpacked)
40G peak, 11±2ms, half-sine
Non-operating (packed)
50G peak, 11±2ms, half-sine
Altitude
Operating
10,000 feet (5
°
C ~ 40
°
C)
Non-operating
40,000 feet (-20
°
C ~ 60
°
C)
ESD
Air discharge
8kV (no error)
12.5kV (no restart error)
15kV (no damage)
Contact discharge
4kV (no error)
6kV (no restart error)
8kV (no damage)