1-27

1.6 Environmental

Requirements

Table 1- 37

Environmental Requirements

Item

Specification

Temperature

Operating (

)

+5~ +35

Non-operating(

)

-20 ~ +60

Humidity

Operating (non-condensing)

20% ~ 85%

Non-operating (non-condensing)

20% ~ 90%

Operating Vibration (unpacked)

Operating

5 - 25.6Hz, 0.38mm; 25.6 - 250Hz, 0.5G

Sweep rate

0.5 octave / minute

Number of test cycles

2 / axis (X,Y,Z)

Non-operating Vibration (unpacked)

Non-operating

5 - 27.1Hz, 0.6G; 27.1 - 50Hz, 0.41mm; 50-500Hz, 2G

Sweep rate

0.5 octave / minute

Number of text cycles

4 / axis (X,Y,Z)

Non-operating Vibration (packed)

Non-operating

5 - 62.6Hz, 0.51mm; 62.6-500Hz, 4G

Sweep rate

0.5 octave / minute

Number of text cycles

4 / axis (X,Y,Z)

Shock

Non-operating (unpacked)

40G peak, 11±2ms, half-sine

Non-operating (packed)

50G peak, 11±2ms, half-sine

Altitude

Operating

10,000 feet (5

°

C ~ 40

°

C)

Non-operating

40,000 feet (-20

°

C ~ 60

°

C)

ESD

Air discharge

8kV (no error)
12.5kV (no restart error)
15kV (no damage)

Contact discharge

4kV (no error)
6kV (no restart error)
8kV (no damage)