7.6.3 Reinstallation

1. Rotate the stroke cam screw clockwise until the slider cam is in a full upward position.
2. Verify that the cover dial indicates the zero stroke setting.
3. Using care not to disturb the adjustment shaft, install the cover assembly, engaging the

drive coupling.

4. Replace the cover screws.
5. Press the adjustment knob down and rotate it clockwise until it stops. (Adjustment is

easier with the drive motor running.) Verify that the cover dial indicates the zero stroke
setting as before; if so, reinstallation is complete and if not, refer to step (6) below for
realignment.

6. To re-align, loosen the screw in the center of the dial cover.
7. Adjust the dial cover to align the pointer with the ‘zero’ mark.
8. Retighten the screw in the center of the dial cover.


7.7 Motor

7.7.1

Removal

1. Disconnect the power source to the drive motor.
2. Disconnect the motor wiring from the motor.
3. Remove the four bolts retaining the motor to the motor adaptor and remove the motor.
4. The coupling is an interlocking jaw design and uses an elastomer spider between the two

coupling halves. One half of the coupling remains on the worm shaft and the other coupling
half on the motor shaft. Loosen the setscrew, which retains the coupling half to the motor
shaft and remove the coupling half, taking care to not lose the shaft key.

7.7.2 Reinstallation

See instructions, Section 4.7

*Note: Motor rotation may be wired for CW or CCW rotation.