Eccentric oil change, Gear oil change – Pulsafeeder Pulsar Shadow User Manual
Page 21
5.4.1
Eccentric Oil Change:
The recommended eccentric oil change interval is two (2) years for normal service and one (1)
year for severe service. The procedure is as follows:
1. Disconnect the power source to the drive motor
2. Relieve all pressure from the piping system.
3. Remove the top cover or controller from the pump.
4. Drain the oil by removing the drain plug on the bottom of the eccentric box.
5. Replace the drain plug.
6. Fill the eccentric box with Pulsalube 9M oil as described under Eccentric Oil Fill
.
7. Replace the top cover or controller.
5.4.2
Gear Oil Change:
The recommended gear oil change interval is five (5) years for normal service and two (2) years
for severe service. The procedure is as follows:
1. Disconnect the power source to the drive motor
2. Relieve all pressure from the piping system.
3. Remove the fill plug from the top of the gearbox.
4. Drain the oil by removing the drain plug on the bottom of the gearbox.
5. Replace the drain plug.
6. Refill with fresh Pulsalube 8G (amber) gear oil as described under Gear Oil Fill.
7. Be sure to replace the top fill plug and side plug.
15