Setup Changes with DIP Switch 1 ON - BP500 (cont.)
Again, You will have 1 minute to complete the setup change after you manually exit Priming Mode.
Immediately after exiting Priming Mode, press this sequence of buttons: Warm*, Light, Warm, Warm, Warm, Warm. Continue
to press Warm until the display shows the Setup Number (S-01, S-02, etc.) you want to switch to. When the correct setup
number is showing, press Light once, and the system will reset, using the newly-selected Setup from that point on.
Move DIP Switch 1 to the OFF position to take the spa out of Test Mode. °F or °C will replace °T.
Using a permanent marker, write the Setup number on the Setup label mounted inside the system lid (right). This is very
important to any service person in the future who may need to replace a circuit board or system and needs to
change the Setup on a replacement part while in the field.
NOTE: Changing the Setup may require wiring changes as well - refer to the wiring diagram or wiring diagram
addendum.
*If the Control Panel does not have a Warm (Up) button, but rather a single Temp button, use the Temp button in place of the Warm
button in the instruction above. (The flow chart assumes a single Temperature Button.)
Indicates Flashing or Changing Segment
Key
A temperature button, used for “Action”
Light or dedicated “Choose” button, depending on control panel configuration
Indicates Alternating or Progressive Message - every 1/2 second
Waiting time - varies depending on function
THIS SYSTEM IS
CONFIGURED AS
SETUP #
SET
SET
The System will reset and go into Priming Mode if the Light Button
is pressed while anything other than the current setup is flashing.
If there is no change to the Setup Number (S-01, S-02, etc.),
the display returns to the SETP screen.
Several Setups can
exist in in this string
A dash (--) indicates the current Setup.
SET
SET
SET
SET
SET
SET
SET
While the Set Temperature is
still flashing, press Light
TEST will now appear in
the LCD first.
SET
RANGE
Main Screen
READY
RANGE FLTR1
Main Screen
READY
RANGE FLTR1
SET
Approx.
5 sec.
or
Approx.
5 sec.
or
SET
SET
SET
SET
When set to ON, Panel will display
alternate readings from
Senor A and Sensor B
on Main Screen
Displays Fault Log