Balboa Water Group BP 60Hz User Manual
Page 30

30
Manufactured under one or more of these patents. U.S. Patents: 5332944, 5361215, 5550753, 5559720, 5,883,459, 6253227, 6282370, 6590188, 6976052, 6965815, 7030343, 7,417, 834 b2,
Canadian Patent: 2342614, Australian patent: 2373248 other patents both foreign and domestic applied for and pending. All material copyright of Balboa Water Group.
4/22/13
A1
A2
A3
A4
A5
A6
A7
A8
A9
A10
SWITCHBANK S1 OFF
SWITCHBANK S1 ON
PART B
BP20MSSH – PN 56373
01-03-13
USE EARTH GROUND CONNECTIONS AS INDICATED INSIDE THE SYSTEM ENCLOSURE
TOTAL OUTPUT AMP DRAW NOT TO EXCEED MAX INPUT RATING OF SPA
A DISCONNECTING MEANS MUST BE INSTALLED WITHIN SIGHT FROM
THE EQUIPMENT AND AT LEAST 5 FEET (1.52 M) FROM THE
INSIDE WALLS OF THE POOL, SPA, OR HOT TUB.
CONNECT ONLY TO CIRCUITS PROTECTED BY A CLASS A GFCI.
FOR SUPPLY CONNECTIONS, USE CONDUCTORS SIZED ON THE BASIS OF
60°C AMPACITY BUT RATED MINIMUM OF 90°C.
TORQUE RANGE FOR MAIN TERMINAL BLOCK (TB1): 27-30 IN. LBS. (31.1-34.5 kg cm)
USE COPPER CONDUCTORS ONLY. EMPLOYER UNIQUEMENT DES CONDUCTEURS DE CUIVRE. #6 AWG MIN. WIRE = 90°
1
PROGRAMMABLE FILTRATION + POLLING
2-SPEED
2-SPEED
1-SPEED
°F
2
PROGRAMMABLE FILTRATION + POLLING
2-SPEED
1-SPEED
1-SPEED
°F
3
PROGRAMMABLE FILTRATION + POLLING
2-SPEED
NONE
1-SPEED
°F
4
NONE
2-SPEED
2-SPEED
1-SPEED
°F
5
NONE
2-SPEED
1-SPEED
1-SPEED
°F
6
NONE
2-SPEED
NONE
1-SPEED
°F
SETUP #
CIRC PUMP
PUMP 1
PUMP 2
MICROSILK®
TEMP SCALE
SYSTEM WILL BE IN
SETUP #1
INSTEAD OF
SETUP #1,
THIS SYSTEM IS
CONFIGURED IN
SETUP #:
PUMP 1 LOW TIMEOUT IS 15 MINUTES.
PUMP 2 IS 2-SPEED IN SETUPS 1 & 4
PUMP 2 IS 1-SPEED IN SETUPS 2 & 5
PUMP 2 IS NOT USED IN SETUPS 3 & 6
LOCATION DEVICE
VOLTS
MAX
AMPS
FROM
TO
J9
2-SP PUMP 1
240V
12A MAX
J46
J72-GROUP 2
J14
2-SP PUMP 2
240V
12A MAX
J18
J3-GROUP 2
PUMP 2 LINE 1 CONNECTION
J19
J10
J15 SPA
LIGHT
12V
1A
J21
CIRC PUMP
120V*
2A MAX
J20
J79-GROUP 4
J32 OZONE
1A
CIRC AND OZONE LINE 1 CONNECTION
J81
J59
J33
TV / AV
120V
3A
J38
J78-GROUP 4
J44 HEATER 240V
5.5
kW
* FOR 240V CIRC PUMP AND OZONE, CONNECT J20 TO J42 (IN GROUP 2)
MICROSILK IS A REGISTERED TRADEMARK OF JASON INTERNATIONAL
TEST MODE OFF
DON’T ADD 1 HS PUMP W/HTR
DON’T ADD 2 HS PUMPS W/HTR
DON’T ADD 4 HS PUMPS W/HTR
SPECIAL AMPERAGE RULE A
STORE SETTINGS*
NOT ASSIGNED
NOT ASSIGNED
NOT ASSIGNED
NOT ASSIGNED
TEST MODE ON
ADD 1 HS PUMP WITH HEAT
ADD 2 HS PUMPS WITH HEAT
ADD 4 HS PUMPS WITH HEAT
SPECIAL AMPERAGE RULE B
MEMORY RESET*
NOT ASSIGNED
NOT ASSIGNED
NOT ASSIGNED
NOT ASSIGNED
*SWITCH #
6
SHOULD BE SET TO OFF UPON FINAL INSTALLATION.
W
iri
ng Diagr
am - BP2
0MSSH, Par
t Number
: 5637
3 (
M
icr
oSilk
, con
t.)