Acceptable ranges for testing equipment – Balboa Water Group BP 60Hz User Manual
Page 23
23
Manufactured under one or more of these patents. U.S. Patents: 5332944, 5361215, 5550753, 5559720, 5,883,459, 6253227, 6282370, 6590188, 6976052, 6965815, 7030343, 7,417, 834 b2,
Canadian Patent: 2342614, Australian patent: 2373248 other patents both foreign and domestic applied for and pending. All material copyright of Balboa Water Group.
42211B
VOLTAGE CHECKLIST
All voltages specified as 120 V or 240 V, may show an
acceptable variance of +/- 10%.
Voltage Ranges
Wire Combo
Voltage +/- 10% Range
Black & Red
240 V 216 V -264 V
Black & White 120 V 108 V -132 V
Red & White
120 V 108 V - 132 V
Black& Green
120 V 108 V - 132 V
Red & Green
120 V 108 V - 132 V
Green & White 0 V
*
*
* Depending on variables such as length of run,
type of wire and temperature, small voltage readings may
sometimes occur between ground and neutral.
MOTOR AMPERAGE GUIDELINES
The following ranges represent general parameters
for many different motors and applications. Check the
device label or with the spa manufacturer to get accurate
amperage draws.
AMPERAGE DRAW RANGES
DEVICE
120 V DRAW
240 V DRAW
Pump low
2 A - 5 A
2 A - 4 A
Pump high
10 A - 14 A
8 A - 12 A
Blower
6 A - 8 A
3 A - 4 A
Acceptable Ranges for Testing Equipment
ACCEPTABLE HEATER AMPERAGE DRAW RANGES
Heater Type
120V Amp Draw
240V Amp Draw
5.5 kW @ 240 V
10.42 A - 12.74 A
20.83 A - 25.48 A
4 kW @ 240 V
7.58 A - 9.26 A
15.15 A -18.52 A
1 kW @ 120 V
7.58 A - 9.26 A
-
ACCEPTABLE HEATER OHM (
Ω) RANGES
Heater Type
Ohms (
Ω
)
5.5 kW @ 240 V
9.42
Ω
-11.52
Ω
4 kW @ 240 V
12.96
Ω
-15.84
Ω
1 kW @ 120 V
12.96
Ω
- 15.84
Ω
TEMPERATURE & HIGH-LIMIT SENSOR OHM TABLE
Temp.
of Sensor
Ohms
(k
Ω
)**
Temp. of
Sensor
Ohms
(k
Ω
)**
40° F
76.686 k
Ω
90° F
22.117 k
Ω
45° F
67.112 k
Ω
100° F
17.636 k
Ω
50° F
58.858 k
Ω
105° F
15.788 k
Ω
60° F
110° F
14.158 k
Ω
70° F
35.533 k
Ω
115° F
12.716 k
Ω
80° F
27.93J k
Ω
120°F
11.439
k
Ω
**Note: 1 k
Ω
= 1000
Ω :
k
Ω
may vary +/- 10% depending on the accuracy of the thermom-
eter and meter used.
Heater Type
Ohms
120V Amp Draw 120V Watts 240V Amp Draw 240V Watts
230V Amp Draw
230V Watts
5.5Kw @ 240V
10.472
11.458
1.37Kw
22.916
5.5Kw
21.961
5.05Kw
5.2Kw @ 240V
11.076
10.834
1.3Kw
21.666
5.2Kw
20.765
4.8Kw
4Kw @ 240V
14.4
8.333
1Kw
16.666
4Kw
15.972
3.7Kw
3Kw @ 240V
19.2
6.25
750W
12.5
3Kw
11.979
2.8Kw
2Kw @ 240V
28.8
4.166
500W
8.333
2Kw
7.986
1.8Kw
1Kw @ 120V
14.4
8.333
1Kw
N/A
N/A
N/A
N/A
HEATER MATRIX