8.15 Programmable settings

8.15.1 Regulation settings

Minimum

setting

Nominal

setting

Maximum

setting

Number of motor starts

starts/day

240

720

720

Minimum stop time 1) sec

5

5

30

Stop between 2 compressor
modules

sec 2 2 5

Start between 2 compressor
modules

sec 2 2 10

Power recovery time 3) sec

10

10

3600

Delay at restarting after
power recovery 3)

sec 0 0 1200

Minimum pressure 2)

8 bar Pack

bar(e)

4

7

7.9

8 bar Full-Feature

bar(e)

4

6.8

7.7

10 bar Pack

bar(e)

4

9

9.9

10 bar Full-Feature

bar(e)

4

8.8

9.7

100 psi Pack

bar(e)

4

7

7.9

100 psi Full-Feature

bar(e)

4

6.8

7.7

125 psi Pack

bar(e)

4

8.1

9

125 psi Full-Feature

bar(e)

4

7.75

8.8

145 psi Pack

bar(e)

4

9

9.9

145 psi Full-Feature

bar(e)

4

8.8

9.7

Maximum pressure 2)

8 bar Pack

bar(e)

4.1

8

8

8 bar Full-Feature

bar(e)

4.1

7.8

7.8

10 bar Pack

bar(e)

4.1

10

10

10 bar Full-Feature

bar(e)

4.1

9.8

9.8

100 psi Pack

bar(e)

4.1

8

8

100 psi Full-Feature

bar(e)

4.1

7.8

7.8

125 psi Pack

bar(e)

4.1

9.1

9.1

125 psi Full-Feature

bar(e)

4.1

8.9

8.9

145 psi Pack

bar(e)

4.1

10

10

145 psi Full-Feature

bar(e)

4.1

9.8

9.8

For Full-Feature also 4)

Dewpoint warning
temperature

°C 3 15

40

Delay at signal 5) sec 0

3

10

Delay at starting 6) sec

0

255 255