beautypg.com

Atlas Air Compressor User Manual

Page 36

background image

Instruction book

2920 1521 00

36

7.3 Overload relays for SF1-8


Frequency Voltage

SF1
single-
phase

SF2
single-
phase

SF2
3-phase

SF4
3-phase

SF6
3-phase

SF8
3-phase

IEC

50 Hz

230 V

12 A

14.5 A

8.3 A

14 A

8.3 and 14 A

2x 14 A

50 Hz

400 V

4.8 A

8.2 A

4.8 and 8.2 A

2x 8.2 A

60 Hz

380 V

5.1 A

8.5 A

5.1 and 8.5 A

2x 8.5 A

50 Hz

500 V

3.8 A

6.5 A

3.8 and 6.5 A

2x 6.5 A

CSA/UL

60 Hz

230 V

10.2 A

14.7 A

9.2 A

15.3 A

9.2 and 15.3 A 2x 15.3 A

60 Hz

440/460 V

4.6 A

7.7 A

4.6 and 7.7 A

2x 7.7 A


Note: SF6 Twin have compressor modules of a different size, the first value is valid for the smaller
SF2 module and the second one is valid for the bigger SF4 module

7.4 Overload relays for SF6-15 Multi


Frequency Voltage

SF6

3-phase

SF8
3-phase

SF11
3-phase

SF15
3-phase

IEC

50 Hz

230 V

8 and 14 A

2x 14 A

3x 14 A

4x 14 A

50 Hz

400 V

4.8 and 8 A

2x 8 A

3x 8 A

4x 8 A

60 Hz

380 V

5 and 8.5 A

2x 8.5 A

3x 8.5 A

4x 8.5 A

50 Hz

500 V

3.6 and 6.4 A 2x 6.4 A

3x 6.4 A

4x 6.4 A

CSA/UL

60 Hz

230 V

9 and 15 A

2x 15 A

3x 15 A

4x 15 A

60 Hz

440/460 V

4.5 and 7.5 A 2x 7.5 A

3x 7.5 A

4x 7.5 A

60 Hz

575 V

3.5 and 5.5 A 2x 5.5 A

3x 5.5 A

4x 5.5 A


Note: SF6 have compressor modules of a different size, the first value is valid for the smaller SF2
module (lower element) and the second one is valid for the bigger SF4 module (higher element)