Instruction book

2920 1521 00

43


Line Indicates

Remarks

1

Sensor which is active
and the actual reading

The unit for pressure can be bar, psi or kg/cm

2

depending on the

programmed selection. The unit for temperature can be °C or °F.
See section 8.12.

2 -

-

3 Compressor

status

Examples:

-

Compressor Off

-

Compressor Running

3 Shut-down

If the unit is shut down, the regulator will automatically show a shut-
down message on the display (see section 8.3). It remains possible
to have a closer look at other parameters related to the shut-down
by means of the menus.

3 Service

required

Indicates that the unit needs servicing. Consult section 8.13 to find
out the exact cause for this message.

3 Sensor

error

Indicates that a sensor is out of order:
-

Outlet pressure transducer

-

On Full-Feature compressors, the dewpoint sensor

Stop the compressor. Switch off the voltage and depressurize the
compressor. Check the sensor wiring. Replace the sensor or
transducer, if necessary.

3 Remote

control

Indicates that the compressor is set in remote control. Consult Atlas
Copco.

4

Functions of keys
below display

See section 1.5.7.

Symbols:

Indicating the status of each compressor module

-

indicating that the compressor module is available (ready to run)

indicating that the compressor module is running

- (blinking)

indicating that the compressor module is not available (due to
minimum stop time or too many starts)

4

* (blinking)

indicating that the compressor module is shut down


Note

When more than one message needs to be displayed (e.g. both warning and service), the
messages will be displayed one after the other for 3 seconds.


Press key (F3) on the main screen to check which compressor module is running or stopped.

Element 1

Stopped

Element 2

Running

Element 3

Stopped

Menu

F1 F2 F3

Fig. 8.3 Element status screen, typical example