Instruction book

2920 1521 00

24

2.3 Electrical connections


General

The electrical installation must correspond to the local codes. The mains supply and earthing lines
must be of suitable size. See section 7.1.

The installation must be earthed and protected by fuses in each phase. An isolating switch must be
installed near the compressor. Make sure that this switch is open to isolate the compressor from
the mains before carrying out any connection.


Connections

Skid - Tank-mounted - Twin
Connect the cable to terminals 1 and 3 (single-phase) or to terminals 1, 3 and 5 (3-phase) of pressure
switch (4-Fig. 1.10). Connect the earthing conductor to the earthing terminal. SF Twin have a
pressure switch for each compressor module; provide for each pressure switch separate supply
cables.

9820 3744 61

55103D

(1)

9820 3744 60

55104D

(1)

Single-phase 3-phase


Fig. 2.7 Service diagram, SF Skid - Tank-mounted – Twin

Text on Fig. 2.7

(1) Customer’s installation