8.7 Modify parameters menu


Function

The menu allows the operator to program:
-

Parameters, see section 8.8.

-

Protections settings, see section 8.9.

-

Service plan settings, see section 8.10.

-

Clock function settings, see section 8.11.

-

Configuration settings, see section 8.12.


8.8 Modifying parameters


Function

To modify a number of parameters as mentioned below and in Fig. 8.1.

-

Pressure Band 1 High

-

Pressure Band 1 Low

-

Pressure Band 2 High

-

Pressure Band 2 Low

-

Number Of Starts/Day (per compressor module)

- Minimum Stop Time (i.e. the time period during which the compressor, if stopped automatically,

remains stopped whatever happens with the air net pressure)

-

Power recovery time (if automatic restart after voltage failure is activated) 3)

-

Restart delay (can be programmed, allowing e.g. compressors to be restarted one after the other)

-

Time to next start (time between the starting of two compressor modules)

-

Time to next stop (time between the stopping of two compressor modules during regulation)


Procedure

1. Starting from the Main screen (see section 8.1.2):

-

press the key "Menu" (F1)

- press

the

↓ key until the option "Modify Parameters" is followed by a horizontal arrow

-

press the tabulator key (5) to activate the menu

2. The first option ("Parameters") will be followed by a horizontal arrow.
3. Press the tabulator key (5): the first item ("Pressure Band 1 High") and its setting will appear.
4. Use

the

↓ key to scroll until the parameter to be modified is followed by a horizontal arrow.