beautypg.com

Atlas Air Compressor User Manual

Page 50

background image

Instruction book

2920 1521 00

50

8.8.1 Modifying the pressure bands


If desired, the operator can program two pressure bands (band 1 and band 2) with different pressure
settings. The settings for band 1 are indicated as "Pressure Band 1 High" and "Pressure Band 1
Low", the settings for band 2 are indicated as " Pressure Band 2 High " and " Pressure Band 2 Low ".


Example:

For pressure band 1:
-

Pressure Band 1 Low:

6.8 bar

-

Pressure Band 1 High:

7.8 bar


For pressure band 2:
-

Pressure Band 2 Low:

5.5 bar

-

Pressure Band 2 High:

6.5 bar



Procedure

1. Consult the section above to select the parameter Pressure Band 1 High:

Pressure Band 1 High

7.8 bar

Pressure Band 1 Low

6.8 bar

Pressure Band 2 High

6.5 bar

Menu Modify
F1 F2 F3

Fig. 8.11 Modify parameters menu


2. The screen shows that the current setting of Pressure Band 1 High is 7.8 bar(e). To modify this

setting, press the key "Modify" (F2):

Pressure Band 1 High

7.8 bar

Program Limits

Cancel

F1 F2 F3

Fig. 8.12 Modify parameters menu


3. The key "Limits" (F2) can be used to find the limitations for the parameter. Use the

↓ or ↑ arrow

key to change the value.

4. Press the key "Program" (F1) to program the new setting or the key "Cancel" (F3) to cancel the

modification operation.

5. The procedure to modify the Pressure Band 1 Low is similar to the description above.
6. If required, repeat the procedure for the Pressure Band 2 High and Pressure Band 2 Low

(pressure band 2).