beautypg.com

Atlas Air Compressor User Manual

Page 45

background image

Instruction book

2920 1521 00

45

8.3 Status data menu


The status data submenu gives information regarding the status of the compressor protection
functions (shut-down, service warning and warning) and allows resetting of a shut-down and service
condition.

Procedure

Starting from the Main screen (see section 8.1.2):
-

Press the key "Menu" (F1), the option "Status data" will be followed by a horizontal arrow

-

Press the tabulator key (5)


8.3.1 No message exists


In this case, LED (7) is out and the message on the display indicates that all conditions are normal
(Fig. 8.5):

All Conditions are OK

Menu Help
F1 F2 F3

Fig. 8.5 Example of a status data screen


8.3.2 A shut-down message exists


In case the compressor is shut down, LED (7) will blink. A shut-down message exists after an
emergency stop or after the temperature switch (TSHH20-Fig.2.8) has tripped (indicated on the
display as Aux. Equipment Overload).

In case of a shut-down due to an emergency stop, a screen similar to the one below will appear:

Emergency Stop

Open

Shutdown Open

Menu ***

*** Reset

F1 F2 F3

Fig. 8.6 Example of a status data screen



1. The indicators (***) are blinking. The screen shows that the compressor is shut down due to an

emergency stop. The contacts of the emergency switch are open. The setting of the shut-down is
open.