beautypg.com

A&D Waterproof Digital Platform Scale HW-60KV-WP User Manual

Page 58

background image

Page 56

HV-WP/HW-WP Series

17.2. OP-03, Options

17.2.

17.2.

17.2.

17.2. RS-232C/ Relay output/ Buzzer (OP-03)

RS-232C/ Relay output/ Buzzer (OP-03)

RS-232C/ Relay output/ Buzzer (OP-03)

RS-232C/ Relay output/ Buzzer (OP-03)

Note When the OP-03 is used, be sure to set the "Address (

f11

) " to "(

00

)".

This option replaces the RS-232C interface, refer to "16. RS-232C Serial Interface"
for specification of RS-232C.

The following option cables can be used, when you do not use the relay output.

Pin connections

Pin No. Signal name

Direction

Description

A

1

HI

Output

Relay output of HI

A

2

RXD

Input

Receive data

A

3

TXD

Output

Transmit data

A

4

LO

Output

Relay output of LO

A

5

SG

-

Signal ground (RS-232C)

A

6

OK

Output

Relay output of OK

A

7

DSR

Output

Data set ready

A

8

COM

-

Relay common terminal

A

Adaptable connector

DIN 8pin, JA:TCP0586 (of accessory)

Circuits

Relay

Solid-state-relay

Maximum voltage

DC50V

Maximum current

DC100mA

Maximum resistance

8