5. Installing the Scale

5.

5.

5.

5. Installing the Scale

Installing the Scale

Installing the Scale

Installing the Scale

This procedure includes all of the steps for installing the HV-WP series and HW-WP
series. Therefore, on some products, there are some unnecessary steps.

Step 1 Connect the indicator unit to the pole with the

accesory knobs and rubber washers.

Step 2 Take the base unit and pole out, taking care

that the load-cell cable is not pulled.

Step 3 Put the weighing pan on the base unit.

Step 4 Insert the remainder of the load cell cable

into the pole. Attach the pole to the bracket

of the base unit so as not to damage the load

cell cable. Affix the pole to the bracket using

two 3mm Allen screws.

Step 5 Select the place for installing the scale. Also

consider "4. Caution" on page 7.

Step 6 Adjust the level of the base unit by using the

"Bubble spirit level" and "Leveling foot".

Step 7 Ground the scale using the earth terminal.

Caution

Please confirm that the local voltage and
the receptacle type are correct for your
scale.

Step 8 Adjust the angle of the indicator unit using

the knobs on the side of indicator unit.

Step 9 Check the weighing accuracy. If the scale

needs calibration, refer to "14. Calibration".