A&D Waterproof Digital Platform Scale HW-60KV-WP User Manual
Page 20
Page 18
HV-WP/HW-WP Series
7. Basic Operation
7.3.
7.3.
7.3.
7.3. Weighing Range for
Weighing Range for
Weighing Range for
Weighing Range for the
the
the
the HV-WP series
HV-WP series
HV-WP series
HV-WP series
This is the function to select a weighing range for the HV-WP series.
The mass value is displayed within a selected range.
There is the automatic range (f2 0) and manual range (f2 1) using the
RANGE
switch.
Operation and Performance
Function table
Meaning and purpose
A
f2 0
Automatic range
The weighing range changes automatically, if the weighing
value proceeds from narrow range to wide range when
placing articles on the weighing pan.
When there is nothing on the weighing pan and the zero point
mark is displayed, it changes to the minimum range
automatically.
Press the
ZERO
switch to change to the minimum range,
when there is nothing on the weighing pan and the zero point
mark is not displayed due to net display or zero error.
A
A
A
A
A
A
A
A
A
f2 1
Manual range
Press the
RANGE
switch to expand the range.
Press the
RANGE
switch to change to the minimum range,
when there is nothing on the weighing pan and the zero point
mark is displayed.
Press the
ZERO
switch and the
RANGE
switch to change to
the minimum range, when there is nothing on the weighing
pan and the zero point mark is not displayed due to net display
or zero error.
A
A
A
A
A
A
A
A
A
Weighing Range
Products
Weighing Range
A
HV-15KV-WP
3kg,
6kg,
15kg
A
HV-60KV-WP
15kg,
30kg,
60kg
A
HV-200KV-WP
60kg,
150kg,
220kg
A