Faults without display on the console, Additional faults for the b 250 ri – Karcher B 250 R I Bp User Manual
Page 27
-
11
Faults without display on the console
Fault
Remedy
Appliance cannot be started
Insert battery plug.
Set main switch to “1”.
Unlock the emergency stop switch.
Check fuse F1, replace if required. *
Check battery; charge it, if needed
Insufficient water quantity
Check fresh water level, refill tank if necessary.
Check hoses for blockages; clean if required.
Clean the fresh water filter.
Open the fresh water ball valve.
Insufficient vacuum perfor-
mance
Clean the seals between dirt water reservoir and cover and check for tightness, replace if required.
Clean the flat-fold filters at the suction support of the suction turbine.
Clean the vacuum lips on the vacuum bar, replace if required
Check suction hose for blockages; clean if required.
Check the suction hose for tightness; replace if required.
Check if the cover on the dirt water discharge hose is closed
Check the setting of the vacuum bar.
Insufficient cleaning result
Set/ adjust contact pressure.
Select a more intensive cleaning program.
Check the brushes for wear, replace if required.
Brushes do not turn
Reduce contact pressure.
Check if foreign matters block the brushes; remove foreign matter if required.
Optional overall lamp and/or
working lamp is not functioning
Check fuse F3, replace if required. *
* The fuses are located in the flat insertion sockets on the wiring plate and can be accessed by opening the front panel.
Additional faults for the B 250 RI
Fault
Remedy
Machine is not sweeping properly
Check roller brushes and/or side brushes for wear, replace if necessary.
Roller brush does not rotate; check drive belt; remove dirt, if required.
Check function of bulk waste flap
Check sealing strip for wear, adjust or replace as required.
Sweeper generates a cloud of dust
Empty waste container
Check drive belts for suction turbine of sweeper.
Check sealing cover on suction fan
Check dust filter, clean or replace.
Check filter case seal
Check sealing strips for wear, adjust or replace as required
Poor cleaning performance at edges
Set the inclination of the side-brushes; adjust, if required.
Replace the side brushes
27