beautypg.com

Troubleshooting – Karcher IB 7-40 Advanced User Manual

Page 19

background image

-

7

1 Screw
2 Lower part
3 Nut
4 Disc
5 Filter inlay
6 Upper section

Loosen 4 screws.

Remove the lower part.

Unscrew the nut.

Remove the disc.

Remove the filter inlay and replace it
with a new filter inlay.

Reassemble the water separator in the
reverse sequence.

According to the specifications of BDV D
26, the following tests must be conducted
by a technical expert. The results of the
tests must be documented in a test report.
The device operator must carefully store
the test report until the next test.

Check the device to see that it is in a
proper condition and is functioning well.

Check the device to see that it is in a
proper condition, is functioning well and
has been installed properly.

Check the device to see that it is in a
proper condition, is functioning well and
has been installed properly.

ƽ

Danger!

Risk of accident while working on the appli-
ance. Carry out all the steps described in
the chapter "Shut down" before starting
anhy work on the device.

ƽ

Danger

Risk of cold burns on account of dry ice or
cold parts of the machine. While working on
the machine, wear appropriate safety gear
for protection against cold or remove dry
ice and let the machine heat up.
Never put dry ice in your mouth.

Maintenance Works

Replace the filter insert in the water sep-
arator.

Tests

After a working break of more than one
year

After changing the installation site

The operational safety of the device
can get hampered on account of main-
tenance jobs or any modifications that
have been done.

Troubleshooting

Faults with display

Display

Indicator lamp
(KL)

Possible cause

Remedy

By whom

E001

KL control voltage
glows red

Control voltage too low

Turn off the appliance, wait briefly, turn on the appli-
ance once again.
Have the socket checked.
If this error recurs, please contact the Kärcher cus-
tomer service department

Operator

E002

KL emergency stop
glows red

Emergency-stop button has
been pressed.

Release emergency-stop button by turning.

Operator

E003

KL compressed air
glows red

Pressure of the compressed air
supply too low

Increase the pressure.
Turn off the appliance, wait briefly, turn on the appli-
ance once again.

Operator

E004

KL dosing glows
red

Interference in the dosing

Turn off the appliance, wait briefly, turn on the appli-
ance once again.
If this error recurs, please contact the Kärcher cus-
tomer service department

Operator

E005

KL jet pistol glows
red

Connection between the de-
vice and the jet pistol is faulty.

Check for correct connection of the couplings in the
control line.
Check control cable for damages.

Operator

E006

KL jet pistol glows
red

Short in jet pistol or control ca-
ble

Replace the jet pistol or the jet hose with a control ca-
ble.

Operator

E007

KL compressed air
glows red

Fault in the compressed air
regulator valve

Call Customer Service.

Operator

E008

KL jet pistol glows
orange

The trigger of the jet pistol was
activated during the switch-on
process or the releasing of the
emergency stop key.

Release the trigger of the jet pistol.

Operator

19