Swiftech APOGEE1 U 775 User Manual
Swiftech Computer Accessories
Copyright Swiftech 2006 – All rights reserved – Last revision date: 5-16-06 – One or more Patents Pending
Rouchon Industries, Inc., dba Swiftech – 1703 E. 28
th
Street, Signal Hill, CA 90755 – Tel. 562-595-8009 – Fax 562-595-8769 - E Mail:
[email protected] – URL:
http://www.swiftnets.com
- Information subject to change without notice
One or more Patents pending
This product is intended for expert users. Please consult with a qualified technician for installation. Improper
installation may result in damage to your components. Swiftech™ assumes no liability whatsoever, expressed or
implied, for the use of these products, nor their installation. The following instructions are subject to change without
notice. Please visit our web site at
www.swiftnets.com
for updates.
Processor compatibility: Intel® Pentium® 4, Pentium® D, Celeron®, Celeron® D (socket LGA 775)
Packing List
COMPONENT ID
COMPONENT DESCRIPTION
QTY
USAGE
SHCS006C0006SS
6-32X3/8 SOCKET CAP SCREW
4.00
WATER-BLOCK
ASSEMBLY
O-RING 3/32
B1000-133 O-RING 3/32 X 1 13/1
1.00
WATER-BLOCK
ASSEMBLY
MCW60-H
MCW60 WATERBLOCK HOUSING
1.00
WATER-BLOCK
ASSEMBLY
MCW60-775-BRKT
MCW60 775 HOLD-DOWN PLATE
1.00
WATER-BLOCK
ASSEMBLY
APOGEE-BP
APOGEE BASE PLATE
1.00
WATER-BLOCK
ASSEMBLY
B1000-2.5X50
BUNA-N 70D BLACK O-RING
2.00
FITTINGS
PM4S-6BN
1/4" - 1/8 NPSM TO 3/8" ID
2.00
FITTINGS
PM4S-8BN
1/4" - 1/8 NPSM TO 1/2 ID
2.00
FITTINGS
22HC04688 15/32"
HOSE
CLAMP
2.00
FITTINGS
22HC0672B
43/64" PREMIUM HOSE CLAMP
2.00
FITTINGS
6-32 HEX CAP
6-32 ACORN NUT
4.00
MOUNTING HARDWARE
LOCKWASHER6
LOCK WASHER #6
6.00
MOUNTING HARDWARE
FW140X250X0215FB BLK
BLACK FIBER WASHER .140X.250X.
10.00 MOUNTING HARDWARE
6-32 NUT
6-32 NUT
4.00
MOUNTING HARDWARE
6-32 X 1”
6-32 X 1 PHIL PAN M/S SZ
4.00
MOUNTING HARDWARE
ARCTIC CÉRAMIQUE
ARCTIC CÉRAMIQUE
1.00
THERMAL COMPOUND
7/64 HEX KEY
TOOL
1.00
MAINTENANCE
1. Preliminary steps & guidelines
Two sets of hose barb fittings are supplied to accommodate high-performance circuits: 3/8” barbs,
and ½” barb.
The Apogee water-block may be installed in any direction
The inlet and outlet are interchangeable with respect to flow direction.
Install the fittings with their o-rings into the water-block before you install the water-block to the
motherboard. Tighten each fitting until the flange of the fitting mates with the ledge of the
water-block o-ring groove, then lock the fitting by fastening another ¼ to ½ turn.
Remove the existing heatsink from your motherboard.
Apply the provided Arctic Céramique thermal compound to the CPU following the comprehensive
installation instructions provided here:
http://www.arcticsilver.com/ceramique_instructions.htm
Install the Apogee water-block following the individual installation schematics for each type of CPU
socket provided hereafter.
Connect the tubing to the water-block hose-barbs. Use the provided hose-clamps to secure the
tubing to the barbs.