0 service connections – Blodgett SB-16G User Manual
Page 4

4
1.0 SERVICE CONNECTIONS
ELECTRICAL CONNECTION: 1/2" conduit connection to controls. 120VAC-60Hz-1PH 2 AMPS per compartment or to be as specified on data plate.
COLD WATER: 3/8" O.D. tubing at 25-50 PSI(170-345 kPa)
STEAM TAKE-OFF CONNECTION: 3/4"IPS optional to operate adjacent equipment.
DRAIN: 2"IPS piped to open floor drain. No Solid Connection.
GAS CONNECTION: 3/4"IPS supply line required.
S
AVAILABLE CABINET WIDTH
GAS SUPPLY
41.0
140,000
300,000
200,000
250,000
87.9
73.3
58.6
BTU/HOUR
kW/HOUR
YES
YES
YES
NO
NO
YES
YES
YES
24"
36"
WATER COLUMN PRESSURES
NATURAL
PROPANE
Water quality is the major factor affecting the performance of your appliance. If you are unsure of water quality, consult a
local water treatment specialist and have the water analyzed. Your water supply must be within these general guidelines:
Water which fails to meet these standards should be treated by installation of water conditioner.
FAILURE OR MALFUNCTION OF THIS APPLIANCE DUE TO POOR WATER QUALITY IS NOT COVERED UNDER WARRANTY.
Total dissolved solids
Total alkalinity
Silica
Chlorine
pH Factor
Less than 13 PPM
Less than 1.5 PPM
7.0-8.5
WATER QUALITY STATEMENT
Less than 60 PPM
Less than 20 PPM
[178mm-355mm]
7" - 14"
[279mm-355mm]
11" - 14"
REAR FLANGED FOOT DETAIL
7/16" [11mm] HOLES
ON 2.5 [63] B.C.
2 EQUALLY SPACED Ø
DIMENSIONS ARE IN INCHES [MM]
S
A
28 [711]
6 [152]
0 [0]
24 [610]
C
8.75 [222]
5.75 [146]
B
S
16
.7
5
[4
25
]
33
[8
38
]
6.25 [159]
24 [610]
5.75 [146]
3.5 [89]
2.75 [70]
25
[6
35
]
8 [203]
S
9.5 [241]
2.5 [64]
0 [0]
36” cabinet
3 [76]
SB-6G and SB-10G TOP VIEW
10 [254]
2.5 [64]
0 [0]
3.5 [89]
29
16
.7
5
[7
56
]
S 8 [203]
6.75 [171]
3.5 [76]
36 [914]
33
[8
38
]
24
.7
5
[6
29
]
SB-16G TOP VIEW
26.75 [679]
MODEL
SB-6G
SB-10G
SB-16G
STD INPUT
140,000
200,000
300,000
A
SB-6G
SB-10G
SB-16G
55.5 [1410]
68.5 [1740]
67 [1702]
C
B
12.5 [318]
12.5 [318]
6 [152]
14.75 [375]
14.75 [375]
13.5 [343]
DIMENSIONS