Operation – Blodgett SB-E Series User Manual
Page 12

10
OM-E-SB
Operation
A. Controls
Operating controls are located on the front panel of the unit.
a.
The on/off switch starts the unit or shuts it off.
b. The RESET indicator lights to show that the boiler has filled with water and
that the heater element contactors can close.
c. The start switch (momentary) closes the heater element contactors. It also
restarts the unit if electrical power is interrupted, or if a low water condition
in the boiler disables the unit.
d. Timers are located on the front right side of the unit. There are two timers
— one each for the upper and lower cavities.
The timer is used in two ways:
1. Turning the timer to any setting delivers steam to the cavity until the
timer runs down to OFF. At that time a red LED switches on and a
beeper sounds and the steam flow to the compartment stops.
2. When turned all the way to the ON position, the timer allows
continuous steaming. A green LED is turned on, and the timer does not
time down. Steam continues until the timer knob is turned to the OFF
position.
WARNING
ALL POTENTIAL USERS OF THE EQUIPMENT
SHOULD BE TRAINED IN SAFE AND CORRECT
OPERATING PROCEDURES.