beautypg.com

Cabling, Table 3. twisted pair cabling and distances – Allied Telesis AT-GS900/8E User Manual

Page 31

background image

AT-GA900/8 and AT-GA900/8E Gigabit Ethernet Switches Installation Guide

31

Cabling

Table 3 contains the cabling specifications for the twisted pair ports.

Note

The twisted pair ports on the switch feature auto-MDI when
operating at either 10 or 100 or 1000 Mbps. Each port is individually
configured as MDI or MDI-X when connected to an end node.
Consequently, you can use either a straight-through or crossover
twisted pair cable when connecting any network device to a twisted
pair port on the switch.

Table 3. Twisted Pair Cabling and Distances

Speed

Type of Cable

Maximum

Operating

Distance

10 Mbps

Category 3 or better 100-ohm
shielded or unshielded twisted pair
cable

100 m (328 ft)

100 Mbps

Category 5 or Category 5E
(Enhanced) 100-ohm shielded or
unshielded twisted pair cable

100 m (328 ft)

1000 Mbps

Category 5 and Category 5E
(Enhanced) 100-ohm shielded or
unshielded twisted pair cable

100 m (328 ft)

This manual is related to the following products: