beautypg.com

Allied Telesis AT-MC1008/SP User Manual

Page 59

background image

AT-MC1008 Series Installation Guide

59

To clean a recessed ferrule using a swab, perform the following procedure.

1. Insert the swab into the adapter as shown in Figure 30. Rub the

ferrule tip with the swab.

Figure 30. Cleaning a Recessed Ferrule

2. If desired, repeat step 1.

3. If a fiber inspection scope is available, use the scope to inspect the

connector to make sure that it is clean and to check for scratches,
pits, or other problems that may affect performance.

Note

Always keep a dust cap on a fiber optic cable when it is not in use.

Warning

Do not look directly at the cable or inspect the cable ends with an
optical lens when the cable is connected at the other end.

157