beautypg.com

A.O. Smith 120 through 250 Series User Manual

Page 80

background image

is

Instruction manual BFC

80

C02 (lock out error)

Error message from the

appliance controller.

Incorrect reference

voltage from the AD

converter.

1. Reset electronic controller.
2. Check that the frequency of the power supply is

compliant

(3.4.2 "General and electrical specifications")

. If this

is not the case, contact your installation engineer

3. If the frequency is correct but the error persists, replace the

electronic controller.

To replace the necessary parts, you must contact your installation

engineer

Internal error message

from the appliance

controller.

EEPROM read
error

50 Hz error

Internal
communication
error

Internal error message

from the appliance

controller.

Gas valve relay
error

Safety relay error

Ignition relay error

RAM error

EEPROM error

EEPROM contents
do not match the
software version

Processor software
error

C03 (blocking error)

Reset error

Too many resets in too

short a period.

Wait for the error to disappear (maximum 1 hour). If the error does

not disappear, replace the appliance controller.

To replace the necessary parts, you must contact your installation

engineer

C04 (blocking error)

Appliance selection

error

Incorrect appliance

selection / Incorrect

selection resistor

1. Check whether the correct appliance is selected

(12.5 "Display

the selected appliance")

.

2. If the correct appliance is selected, fit the correct selection

resistor.

3. If incorrect appliance selected, select the correct one.

If the error cannot be resolved or is persistent, contact your

installation engineer
To replace the necessary parts, you must contact your installation

engineer

Code + Description

Cause

Solution

Remark