INSTALLATION CHECKLIST

Water Heater Location Requirements

Centrally located with the water piping system.

Located as close to the gas piping and vent

pipe system as possible.

Located indoors and in a vertical position.

Protected from freezing temperatures.

Proper clearances from combustible surfaces

maintained and not installed directly on a

carpeted floor. Sufficient room to service the

water heater.

Provisions made to protect the area from water

damage. Properly sized drain pan installed and

piped to an adequate drain.

Installation area free of corrosive elements and

flammable materials.

Vent Pipe System

Draft hood and damper properly installed

Vent connectors securely fastened with screws

and supported properly to maintain 6” (152mm)

clearance.

Vent pipe and fittings of approved material.

Acceptable size, length, and number of elbows

on exhaust outlet pipe.

Installed in accordance with prevailing

provisions of local codes, or in the absence of

such, National Fuel Gas Code, NFPA 54, ANSI

Z223.1-Latest Edition. Canadian Installations

must be performed in accordance with

CAN/CSA-B149.1.

Drafthood or vent pipe should not be obstructed

in any way.

Vent Termination

Vertical

Vertical gas vents must terminate with a listed

cap or other roof assembly and be installed

according to their manufacturer’s instructions.

Water System Piping

Temperature and pressure relief valve properly

installed with a discharge line run to an open

drain and protected from freezing.

All piping properly installed and free of leaks.

Water heater completely filled with water.

A properly sized expansion tank must be

installed on all closed systems.

A tempering valve should be installed per

the manufacturer’s instructions.

Gas Supply and Piping

If using a flexible gas connector, make sure its

rating tag matches or exceeds the input of the

water heater.

Adequate pipe size and of approved material.

Gas supply is the same type as listed on the

water heater data plate.

Gas line equipped with full opening shut-off

valve, union and drip leg.

Approved pipe joint compound used.

Chloride-free soap and water solution or other

approved means used to check all connections

and fittings for possible gas leaks.

Electrical Connections

Unit must be “hard-wired” to a dedicated 120V

power supply

Proper polarity.

Water heater properly grounded.

Installed in accordance with prevailing

provisions of local codes, or in the absence of

such, National Electrical Code, ANSI/NFPA 70

and/or the CSA C22.1, Electrical Code.