Gas Pressure Testing

Important: This water heater and its gas connection

must be leak tested before placing the appliance in

operation.

If the code requires the gas lines to be tested at

a pressure of 14” W.C. or greater, the water

heater and its manual shut-off valve must be

disconnected from the gas supply piping

system and the line capped.

If the gas lines are to be tested at a pressure

less than 14” W.C., the water heater must

be isolated from the gas supply piping system

by closing its manual shut-off valve.

U.L. recognized fuel gas and carbon monoxide(CO)

detectors are recommended in all applications and

should be installed using the manufacturer’s instruc-

tions and local codes, rules, or regulations.

Note: Air may be present in the gas lines and could

prevent the burner from lighting on initial start-up. The

gas lines should be purged of air by a qualified service

technician after installation of the gas piping system.

Explosion Hazard

Have a qualified service technician make

sure L.P. gas pressure does not exceed

13” water column.

Failure to do so can result in death,

explosion, or fire.