beautypg.com

Electrical connections – American Water Heater DCG User Manual

Page 16

background image

16

If you lack the necessary skills required to properly

install the electrical wiring to this water heater, do not

proceed but have a qualified service technician perform

the installation.

When making the electrical connections, always make

sure:

The voltage and frequency correspond to that

specified on the water heater data plate on the

front of the water heater.

The electrical supply has the proper overload

fuse or breaker protection. The water heater

draws less than 7 amps.

Wire sizes and connections comply with all

applicable codes.

Wiring is enclosed in approved conduit

(if required by local codes).

The water heater and electrical supply are

properly grounded.

This water heater must be “hard-wired” do not

use an extension cord to supply electrical

power to this water heater.

Note: The wiring diagram can be found on page 17.

Always reference the wiring diagram(s) for the correct

electrical connections.

Caution: Label all wires prior to disconnection when

servicing controls. Wiring errors can cause improper

and dangerous operation. Verify proper operation after

servicing.

Electrical Installation

1. Shut off the power at the electrical service box.

2. Loosen the screws securing the access panel to

the electrical compartment. (The electrical wiring

diagram can be found on the inside of the access

panel.) Set the access panel aside.

3. Connect the electrical supply to the water heater

in accordance with local utility requirements and

codes or, in the absence of local codes, with the

National Electrical Code, ANSI/NFPA 70 and/or the

CSA C22.1, Electrical Code. Use only a dedicated

electrical circuit containing a properly sized fuse or

circuit breaker. Maximum overload protection

should not exceed 15 Amperes.

4. Connect this circuit (directly from the electrical

service box) to an electrical disconnect switch.

5. Ground the water heater by connecting the

electrical service ground wire to the green ground

wire (provided).

Note: The power supply to this water heater must be

properly polarized, [120 volts from the hot lead (black)

to ground and 0 volts from the neutral lead (white) to

ground] otherwise, the unit will not operate.

6. After making all electrical connections, completely

fill the tank with water and check all connections for

leaks. Open the nearest hot water faucet and let it

run for 3 minutes to purge the water lines of air and

sediment and to ensure complete filling of the tank.

The electrical power may then be turned on.

ELECTRICAL CONNECTIONS

Index

This manual is related to the following products: