MERLIN

TROUBLE SHOOTING

(WIND SPEED)

IF THERE IS WIND......

IF THERE IS NO WIND......

1

2

3

Disconnect the black and white wires from the back of the indicator and connect
them to volt-ohmeter as shown. Set for low range AC Volts.

1

Disconnect the black and white wires from the back of the indicator and connect
them to volt-ohmeter as shown. Set the range for Ohms.

If the sensor delivers the above approximate voltages, then the fault lies in the indicator.
If it does not deliver these voltages, then the fault lies in the sensor or installed wire.

If the sensor is oper

v

ating proper

ou will achie

ly, y

e these approximate readings:

8-9 MPH

= 0.15 VAC rms

17 MPH

= 0.31 VAC rms

51 MPH

= 0.97 VAC rms

102 MPH = 2.00 VAC rms

2

If the sensor and wire are good, the ohm meter should indicate between 500 and
1,000 ohms. If there is a good reading on the ohm meter, then the indicator is at fault.
If the reading is wrong, then the sensor or installed wire is at fault.

FROM AC

ADAPTER

FROM ROOF TOP

SENSORS

VOLT-OHMETER

BLACK AND

WHITE WIRES

Page 6

30 Barnet Boulevard

New Bedford, MA 02745

(508) 995-2200

Select Units of

Measuret

3

AC ADAPTOR

(NO POLARITY)