MERLIN

TROUBLE SHOOTING

(WIND DIRECTION)

IF ALL LEDS LIGHT......

IF THE INSTRUMENT TESTS OKAY......

2

1

Perform the latch up corrections as previously detailed.

Disconnect the sensor wires from the back of the meter.

Reconnect the wind direction wires. If there is still a fault in the wind direction portion, then
the problem is in the wind direction sensor or the installed wire.

3

4

5

6

Connect a jumper wire (a paper clip will suffice) between
terminals #4 and #5. The instrument should indicate “0”
wind speed and “WSW” direction. If it does then continue
to step 4. If not, continue to step 3.

Connect the same jumper wire used in
step 2 to between terminals #3 and #4.
The instrument should now indicate “0”
wind speed and “WSW” direction. If it
does then continue to step 4. If not, the

fault is in the instrument.

Remove the sensor from the roof and
connect it to the indicator with short
pieces of wire.

Rotate the vane slowly and observe the
lights. If it still does not operate properly,
then the fault is in the sensor. Otherwise
the fault is in the installed wire.

The unit will no

m the self test, all LEDS will light f

w perfor

or about 3 seconds. If y

e time

ou do not hav

to check that all LEDS light, repeat the procedure. This will cause the self test to start again. If some
or all of the LEDS do not light, then the fault is in the instrument.

FROM AC

ADAPTER

JUMPER WIRE

(OR PAPER CLIP)

FROM AC

ADAPTER

4

5

RED

WIRE

GREEN

WIRE

Page 5

30 Barnet Boulevard

New Bedford, MA 02745

(508) 995-2200

Select Units of

Measuret

Select Units of

Measuret

3

3

JUMPER WIRE

(OR PAPER CLIP)

Select Units of

Measurment

3

AC ADAPTOR

(NO POLARITY)

AC ADAPTOR

(NO POLARITY)

AC ADAPTOR

(NO POLARITY)