Table 11, At-a-glance specifications – ADTRAN TRACER 5045 User Manual
Page 30

Section 3 Engineering Guidelines
TRACER 5045 System Manual
30
© 2004 ADTRAN, Inc.
612805045L1-1B
Table 11. At-A-Glance Specifications
Hardware
Description
Specification
Transmitter
Output Power
+20 dBm, max
Frequency Range
5725 to 5850 MHz
Receiver
Receive Level, Minimum
-78 dBm
Receive Level, Maximum
-30 dBm
Receive Level, Nominal
-55 dBm
Frequency Plan
Plan A
Tx 5.747 GHz, Rx 5.827 GHz
Plan B
Tx 5.827 GHz, Rx 5.747 GHz
10/100BaseT/TX Interfaces
Connection
four RJ-48C jacks with auto MDI/MDIX crossover
Flow Control
backpressure flow control on all full-duplex interfaces
User Interface
Panel
Alarm LEDs
Diagnostics
RF link diagnostics and error history, transmit and
receive packets history
Test Points
RSSI and Ground (GND)
Alarms
Normally Open (NO) and Normally Closed (NC)
VT100 Terminal
Menu Driven User Interface, Control of the Remote
End, Optional Password Protection, Event History,
Ethernet Statistics
VT100 Terminal Interface
Data Rate
9600 bps
Data Bits
8
Parity
None
Stop Bits
1
Terminal Emulation
VT100
Mechanical and Environmental
Operating Temperature
-25° C to 65° C
Size
17.22” W x 9.34” D x 1.72” H
Humidity
95%, Non-condensing
Weight
7 lbs