Appendix B. Example Programs

;activate SW12V for turbidity probe, delay 3 seconds, then measure
1: Do (P86)
1: 48

Set Port 8 High


2: Excitation with Delay (P22)
1: 1

Ex Channel

2: 0

Delay W/Ex (0.01 sec units)

3: 300

Delay After Ex (0.01 sec units)

4: 0

mV Excitation


3: Beginning of Loop (P87)
1: 0

Delay

2: 10

Loop Count


4: Volt (SE) (P1)

1: 1

Reps

2: 25

2500 mV 60 Hz Rejection Range

3: 1

SE Channel

4: 3

-- Loc [ NTU_V_1 ]

5: 0.001

Mult

6: 0.0

Offset


5: End (P95)

6: Spatial Average (P51)
1: 10

Swath

2: 3

First Loc [ NTU_V_1 ]

3: 2

Avg Loc [ NTU_Volts ]


NTU = -0.29928 + (105.69 * NTU_Volts) - (0.24763 * NTU_Volts^2)

; evaluate to see if value >250, where High range measurement should be taken via Sub1

7: If (X<=>F) (P89)
1: 1

X Loc [ NTU ]

2: 3

>=

3: 250

F

4: 1

Call Subroutine 1


8: Do (P86)

;switch off the 12V for turbidity probe

1: 58

Set Port 8 Low


*Table 2 Program
01: 0

Execution Interval (seconds)


*Table 3 Subroutines

1: Beginning of Subroutine (P85)
1: 1

Subroutine 1


2: Beginning of Loop (P87)

1: 0

Delay

2: 10

Loop Count


3: Volt (SE) (P1)

1:

1

Reps

2:

25

2500 mV 60 Hz Rejection Range

3:

2

SE Channel

4:

3

-- Loc [ NTU_V_1 ]

5:

0.001

Mult

6:

0.0

Offset


4: End (P95)


5: Spatial Average (P51)

1: 10

Swath

2: 3

First Loc [ NTU_V_1 ]

3: 2

Avg Loc [ NTU_Volts ]

B-4