beautypg.com

B.2 csat3 binary data output format – Campbell Scientific CSAT3 3-D Sonic Anemometer User Manual

Page 61

background image

Appendix B. Serial Communications with the CSAT3

Nassi-Shneiderman diagrams are given in FIGURE B-1and FIGURE B-2 for

collecting data using a PC and the RS-232 port. In FIGURE B-1, the PC is the

Trigger Source and the data acquisition system. In FIGURE B-2, the

anemometer is triggered by its internal timer and a PC is the data acquisition

system. Use the logic in FIGURE B-1 when the CSAT3 is measured along

with other analog/digital signals.

FIGURE B-1. PC as the trigger source

FIGURE B-2. CSAT3 as the trigger source

B.2 CSAT3 Binary Data Output Format

Five words are sent by the CSAT3’s RS-232 output. Words 0 through 3 are 16

bit signed integers and word 4 is 16 bit unsigned integer. The five words are

sent starting with word 0 and ending with word 4. A description of each word

is given in TABLE B-2.

B-3