beautypg.com

Campbell Scientific CSAT3 3-D Sonic Anemometer User Manual

Page 30

background image

CSAT3 Three Dimensional Sonic Anemometer

SDMAddress/SDM Address: The unique SDM Address of the CSAT3

connected to the datalogger. In CRBasic dataloggers, the CSAT3 address is

entered as a base ten number. In EDLOG dataloggers, the CSAT3 address is

entered as a base four number (see TABLE 3-1). The SDM Address is

sequentially incremented if the Reps option is greater than 1.

The wind data and the speed of sound (sonic virtual temperature) is scaled by

the instruction into m s

–1

and degrees Celsius.

SDM address 15 (base 10)/33 (base 4) is a special

address used during a Group Trigger. Do not program

the datalogger to address SDM address 15/33.

Command/Option 90: “Trigger and Get Wind & c Data” sends a

measurement trigger to the CSAT3 whose SDM address is specified in

SDMAddress/SDM Address parameter. The CSAT3 also sends data to the

datalogger.

Command/Option 91: “Trigger and Get Wind & T

s

Data” sends a

measurement trigger to the CSAT3 whose SDM address is specified in the

SDMAddress/SDM Address parameter. The CSAT3 also sends wind speed

and sonic virtual temperature (defined in Equation (9) in Appendix C) via the

SDM bus to the datalogger.

Command/Option 92: “Trigger and Get Wind & c-340 Data” sends a

measurement trigger to the CSAT3 whose SDM address is specified in

SDMAddress/SDM Address parameter. The CSAT3 also sends wind speed

and the speed of sound minus 340 m s

–1

via the SDM bus to the datalogger.

Command/Option 97: “Get Wind and c-340 Data After a Group Trigger”.

The CSAT3, specified in SDMAddress/SDM Address parameter, sends wind

speed and the speed of sound minus 340 m s

–1

to the datalogger. A new

measurement is not triggered. The CSAT3 ()/SDM-CSAT3 (P107) Instruction

must be preceded by the SDMTrigger/Group Trigger (P110) Instruction to use

this option.

Command/Option 98: “Get Wind and Ts Data After a Group Trigger”. The

CSAT3, specified in SDMAddress/SDM Address parameter, sends the wind

speed and sonic virtual temperature (defined in Equation (9) in Appendix C) to

the datalogger. A new measurement is not triggered. The CSAT ()/SDM-

CSAT3 (P107) Instruction must be preceded by the SDMTrigger/Group

Trigger (P110) Instruction to use this option.

Command/Option 99: “Get Wind and c Data After a Group Trigger”. The

CSAT3, specified in SDMAddress/SDM Address parameter, sends the wind

speed and speed of sound to the datalogger. A new measurement is not

triggered. The CSAT3 ()/SDM-CSAT3 (P107) Instruction must be preceded

by the SDMTrigger/Group Trigger (P110) Instruction.

CAUTION

20