Campbell Scientific CR510 Basic Datalogger User Manual
Campbell Scientific Measuring instruments
Table of contents
Document Outline
- Revision and Copyright Information
- Warranty and Assistance
- Table of Contents
- Features of CR510
- Selected Operating Details
- Cautionary Notes
- CR510 DATALOGGER OVERVIEW
- Section 1
- SECTION 1. FUNCTIONAL MODES
- 1.1 DATALOGGER PROGRAMS - *1, *2, *3, AND *4 MODES
- 1.2 SETTING AND DISPLAYING THE CLOCK - *5 MODE
- 1.3 DISPLAYING/ALTERING INPUT MEMORY, FLAGS, AND PORTS - *6 MODE
- 1.4 COMPILING AND LOGGING DATA - *0 MODE
- 1.5 MEMORY ALLOCATION - *A
- 1.6 MEMORY TESTING AND SYSTEM STATUS - *B
- 1.7 *C MODE -- SECURITY
- 1.8 *D MODE -- SAVE OR LOAD PROGRAM
- SECTION 1. FUNCTIONAL MODES
- Section 2
- Section 3
- SECTION 3. INSTRUCTION SET BASICS
- 3.1 PARAMETER DATA TYPES
- 3.2 REPETITIONS
- 3.3 ENTERING NEGATIVE NUMBERS
- 3.4 INDEXING INPUT LOCATIONS
- 3.5 VOLTAGE RANGE AND OVERRANGE DETECTION
- 3.6 OUTPUT PROCESSING
- 3.7 USE OF FLAGS: OUTPUT AND PROGRAM CONTROL
- 3.8 PROGRAM CONTROL LOGICAL CONSTRUCTIONS
- 3.9 INSTRUCTION MEMORY AND EXECUTION TIME
- 3.10 ERROR CODES
- SECTION 3. INSTRUCTION SET BASICS
- Section 4
- Section 5
- Section 6
- Section 7
- SECTION 7. MEASUREMENT PROGRAMMING EXAMPLES
- 7.1 SINGLE ENDED VOLTAGE107 TEMPERATURE PROBE
- 7.2 DIFFERENTIAL VOLTAGE MEASUREMENT
- 7.3 HMP45C TEMPERATURE AND RH PROBE
- 7.4 ANEMOMETER WITH PHOTOCHOPPER OUTPUT
- 7.5 TIPPING BUCKET RAIN GAGE WITH LONG LEADS
- 7.6 100 OHM PRT IN 4 WIRE HALF BRIDGE
- 7.7 100 OHM PRT IN 3 WIRE HALF BRIDGE
- 7.8 100 OHM PRT IN 4 WIRE FULL BRIDGE
- 7.9 PRESSURE TRANSDUCER - 4 WIRE FULL BRIDGE
- 7.10 LYSIMETER - 6 WIRE FULL BRIDGE
- 7.11 227 GYPSUM SOIL MOISTURE BLOCK
- 7.12 NONLINEAR THERMISTOR IN HALF BRIDGE
- 7.13 WATER LEVEL - GEOKON'S VIBRATING WIRE PRESSURE SENSOR
- 7.14 4 TO 20 MA SENSOR USING CURS100 TERMINAL INPUT MODULE
- SECTION 7. MEASUREMENT PROGRAMMING EXAMPLES
- Section 8
- SECTION 8. PROCESSING AND PROGRAM CONTROL EXAMPLES
- 8.1 COMPUTATION OF RUNNING AVERAGE
- 8.2 RAINFALL INTENSITY
- 8.3 SUB 1 MINUTE OUTPUT INTERVAL SYNCHED TO REAL TIME
- 8.4 SWITCH CLOSURES ON CONTROL PORTS (RAIN GAGE)
- 8.5 CONVERTING 0-360 WIND DIRECTION OUTPUT TO 0-540 FOR STRIP CHART
- 8.6 USE OF 2 FINAL STORAGE AREAS - SAVING DATA PRIOR TO EVENT
- 8.7 LOGARITHMIC SAMPLING USING LOOPS
- SECTION 8. PROCESSING AND PROGRAM CONTROL EXAMPLES
- Section 9
- SECTION 9. INPUT/OUTPUT INSTRUCTIONS
- 1 SINGLE-ENDED VOLTS
- 2 DIFFERENTIAL VOLTS
- 3 PULSE COUNT
- 4 EXCITE, DELAY, AND MEASURE
- 5 AC HALF BRIDGE
- 6 FULL BRIDGE WITH SINGLE DIFFERENTIAL MEASUREMENT
- 7 THREE WIRE HALF BRIDGE
- 8 DIFFERENTIAL VOLTAGE WITH EXCITATION AND DELAY
- 9 FULL BRIDGE WITH EXCITATION COMPENSATION
- 10 BATTERY VOLTAGE
- 11 107 THERMISTOR PROBE
- 12 207 RELATIVE HUMIDITY PROBE
- 16 TEMPERATURE FROM PLATINUM R.T.D.
- 17 INTERNAL TEMPERATURE
- 18 MOVE TIME TO INPUT LOCATION
- 19 MOVE SIGNATURE INTO INPUT LOCATION
- 20 PORT SET
- 21 PULSE PORT WITH DURATION
- 22 EXCITATION WITH DELAY
- 24 CALIBRATION
- 25 PORT READ
- 26 TIMER
- 27 PERIOD MEASUREMENT
- 28 VIBRATING WIRE MEASUREMENT
- 29 INW PS9105E
- 105 SDI-12 RECORDER
- 106 SDI-12 SENSOR
- 114 SET TIME
- 117 READ DATALOGGER ID
- 130 ERROR MONITOR
- 131 ENHANCED VIBRATING WIRE MEASUREMENT
- SECTION 9. INPUT/OUTPUT INSTRUCTIONS
- Section 10
- SECTION 10. PROCESSING INSTRUCTIONS
- 30 Z = F X 10N
- 31 Z = X
- 32 Z = Z + 1
- 33 X + Y
- 34 X + F
- 35 X - Y
- 36 X * Y
- 37 X * F
- 38 X / Y
- 39 SQUARE ROOT
- 40 LN(X)
- 41 EXP(X)
- 42 1/X
- 43 ABS(X)
- 44 FRACTIONAL VALU E OF X
- 45 INTEGER VALUE OF X
- 46 X MOD F
- 47 XY
- 48 SIN(X)
- 49 SPATIAL MAXIMUM
- 50 SPATIAL MINIMUM
- 51 SPATIAL AVERAGE
- 52 RUNNING AVERAGE
- 53 SCALING ARRAY WITH MULTIPLIER AND OFFSET
- 54 BLOCK MOVE
- 55 5TH ORDER POLYNOMIAL
- 56 SATURATION VAPOR PRESSURE
- 58 LOW PASS FILTER
- 59 BRIDGE TRANSFORM
- 61 INDIRECT INDEXED MOVE
- 63 PARAMETER EXTENSION
- 65 BULK LOAD
- 66 ARCTAN
- 68 EXTENDED PARAMETERS 4 DIGIT
- SECTION 10. PROCESSING INSTRUCTIONS
- Section 11
- Section 12
- SECTION 12. PROGRAM CONTROL INSTRUCTIONS
- 83 IF CASE X < F
- 85 LABEL SUBROUTINE
- 86 DO
- 87 LOOP
- 88 IF X COMPARED TO Y
- 89 IF X COMPARED TO F
- 90 STEP LOOP INDEX
- 91 IF FLAG / PORT / MODEM
- 92 IF TIME
- 93 BEGIN CASE STATEMENT
- 94 ELSE
- 95 END
- 96 ACTIVATE SERIAL DATA OUTPUT
- 97 INITIATE TELECOMMUNICATIONS
- 98 SEND CHARACTER
- 111 RUN PROGRAM FROM FLASH
- 120 TGT1 TELONICS GOES
- 121 ARGOS
- 123 AUTOMATIC PROGRAMMING OF A TGT1
- SECTION 12. PROGRAM CONTROL INSTRUCTIONS
- Section 13
- SECTION 13. CR510 MEASUREMENTS
- Section 14
- SECTION 14. INSTALLATION AND MAINTENANCE
- 14.1 PROTECTION FROM THE ENVIRONMENT
- 14.2 POWER REQUIREMENTS
- 14.3 CAMPBELL SCIENTIFIC POWER SUPPLIES
- 14.4 SOLAR PANELS
- 14.5 DIRECT BATTERY CONNECTION TO THE CR510 TERMINAL STRIP
- 14.6 VEHICLE POWER SUPPLY CONNECTIONS
- 14.7 GROUNDING
- 14.8 TERMINAL STRIP
- 14.9 USE OF DIGITAL I/O PORT (C1) FOR SWITCHING RELAYS
- 14.10 MAINTENANCE
- SECTION 14. INSTALLATION AND MAINTENANCE
- Appendix A
- Appendix B
- Appendix C
- Appendix D
- Appendix E
- Appendix F
- APPENDIX G. TD OPERATING SYSTEM ADDENDUM FORCR510, CR10X, AND CR23X MANUALS
- Revision and Copyright Information
- TD and PakBus Operating System Addendum for CR510, CR10X, and CR23X Manuals
- MEASUREMENT AND CONTROL MODULE OVERVIEW
- SECTION 1. FUNCTIONAL MODES
- 1.5 MEMORY ALLOCATION - ?A
- MEMORY TESTING AND SYSTEM STATUS - ?B
- 1.7 *C MODE -- SECURITY
- 1.8 *D MODE – TRANSFER PROGRAMS, GENERAL SETTING
- 1.8.1 ERASING CURRENT PROGRAM
- 1.8.2 PROGRAM TRANSFER WITH STORAGE MODULE
- 1.8.3 FULL/HALF DUPLEX
- 1.8.4 SET DATALOGGER ID
- 1.8.5 SETTING POWERUP OPTIONS
- 1.8.6 SET INITIAL BAUD
- 1.8.7 SET PROGRAM COMPILE OPTION
- 1.8.8 SET PAKBUS ADDRESS
- 1.8.9 ALLOCATE MEMORY FOR GENERAL PURPOSE FILES
- 1.8.10 VIEW ROUTING TABLE
- 1.8.11 SET PAKBUS ROUTER BEACON INTERVAL
- 1.8.12 PAKBUS NEIGHBOR FILTER
- 1.9 *9 DATA TABLES SIZES.
- SECTION 2. INTERNAL DATA STORAGE
- SECTION 3. INSTRUCTION SET BASICS
- SECTION 8. PROCESSING AND PROGRAM CONTROL EXAMPLES
- 8.1 COMPUTATION OF RUNNING AVERAGE
- 8.2 RAINFALL INTENSITY
- 8.3 USING CONTROL PORTS AND LOOP TO RUN AM416 MULTIPLEXER
- 8.4 INTERRUPT SUBROUTINE USED TO COUNT SWITCH CLOSURES (RAIN GAGE)
- 8.5 SDM-A04 ANALOG OUTPUT MULTIPLEXER TO STRIP CHART
- 8.6 CONVERTING 0-360 WIND DIRECTION OUTPUT TO 0-540 FOR STRIP CHART
- 8.7 LOGARITHMIC SAMPLING USING LOOPS
- SECTION 9. INPUT/OUTPUT INSTRUCTIONS
- SECTION 11. OUTPUT PROCESSING INSTRUCTIONS
- SECTION 12. PROGRAM CONTROL INSTRUCTIONS
- Wireless Networks
- PakBus Get/Send Locations (P190)
- Send Final Storage Data (P191)
- Send Message (P192)
- Wireless Network Master (P193)
- Seconds Until Transmit (P194)
- Use Remote Clock Report (P195)
- Wireless Network Remote (P196)
- Force Route (P197)
- Set Setting (P198)
- Routing Table Information (P199)
- PakBus Settings (Options | PakBus Settings)
- List of Tables
- List of Figures