Campbell Scientific CR510 Basic Datalogger User Manual
Page 58

SECTION 3. INSTRUCTION SET BASICS
3-10
TABLE 3.9-3. Output Instruction Memory and Execution Times R = No. of Reps.
INTER.
MEM. FINAL
PROG.
EXECUTION TIME (ms)
INSTRUCTION
LOC.
VALUES
1
BYTES
FLAG 0 LOW FLAG 0 HIGH
69 WIND VECTOR
2+9R
(2, 3, or 4)R
12
Options 00, 01, 02
4.0 + 17.4R
3.3 + 70.7R
Options 10, 11, 12
3.0 + 16.3R
4.0 + 75R
70 SAMPLE
0
R
6
0.2
0.5+ 0.4R
71 AVERAGE
1+R
R
7
0.6+ 1.1R
1.5+ 4.4R
72 TOTALIZE
R
R
7
0.6+ 1.0R
1.0+ 1.7R
73 MAXIMIZE
(1 or 2)R
(1,2, or 3)R
8
1.0+ 1.2R
5.0+ 3.0R
74 MINIMIZE
(1 or 2)R
(1,2, or 3)R
8
0.8+ 1.2R
5.0+ 3.0R
75 HISTOGRAM
1+bins
∗
R
bins
∗
R
24
0.8+ 3.4R
1.6+ 5.2 + (1.4
∗
bins)R
77 REAL TIME
0
1 to 4
4
0.2
3.8
78 RESOLUTION
0
0
3
0.4
0.4
79 SMPL ON MM
R
R
7
0.4
1.7 + 1.1R
80 STORE AREA
1
0
0
7
0.3
0.3
82 STD. DEV.
1+3R
R
7
1.5+ 2.0R
2.9+ 2.1R
1
Output values may be sent to either Final Storage area or Input Storage with Instruction 80.
TABLE 3.9-4. Program Control Instruction Memory and Execution Times
MEMORY
INTER.
PROG.
INSTRUCTION
LOC.
BYTES
EXECUTION TIME (ms)
83 IF CASE 0 10 0.5 85 LABEL SUBR. 0 3 0 86 DO 0 6 0.3 87 LOOP 1 10 0.3 88 IF X<=>Y 0 11 0.8 89 IF X<=>F 0 13 0.6 90 LOOP INDEX 0 3 0.7 91 IF FLAG/PORT 0 7 0.4 92 IF TIME 1 12 0.4 93 BEGIN CASE 1 8 0.3 94 ELSE 0 4 0.2 95 END 0 4 0.2 96 SERIAL OUT 0 3 Option: 0x 1x 2x 3x Time: 0.4 1.8 2.1 0.9 Option: 4x 5x 6x 7x Time: 1.7 1.9 0.7 0.5 97 INIT.TELE. 7 17 2.3 120 GOES SAT 0 or 2 5 8000 121 ARGOS SAT 0 8 250