Campbell Scientific 4WFBS120, 4WFBS350, 4WFBS1K 4 Wire Full Bridge Terminal Input Modules User Manual
Page 34
4WFBS120, 4WFBS350, 4WFBS1K 4 Wire Full Bridge Terminal Input Modules (TIM)
5: Bulk Load (P65)
1: 5 F ;
Gage09
2: 9 F ;
Gage10
3: 12 F ;
Gage11
4: 4 F ;
Gage12
5: 8 F ;
Gage13
6: 2 F ;
Gage14
7: 8 F ;
Gage15
8: 9 F ;
Gage16
9: 78 Loc [ LeadFt09 ]
6: Beginning of Loop (P87) ;
Calculate lead length resistance:
1: 0 Delay
2: 16 Loop Count
7: Z=X*Y (P36)
1: 70 -- X Loc [ LeadFt01 ]
2: 69 Y Loc [ LeadOhms ]
3: 86 -- Z Loc [ OhmLead01 ]
8: End (P95)
9: Bulk Load (P65) ;
Load strain gauge Gage Factors:
1: 2.095 F ;
Gauge01
2: 2.095 F ;
Gauge02
3: 2.095 F ;
Gauge03
4: 2.095 F ;
Gauge04
5: 2.095 F ;
Gauge05
6: 2.095 F ;
Gauge06
7: 2.095 F ;
Gauge07
8: 2.095 F ;
Gauge08
9: 102 Loc [ GF01 ]
10: Bulk Load (P65)
1: 2.095 F ;
Gauge09
2: 2.095 F ;
Gauge10
3: 2.095 F ;
Gauge11
4: 2.095 F ;
Gauge12
5: 2.095 F ;
Gauge13
6: 2.095 F ;
Gauge14
7: 2.095 F ;
Gauge15
8: 2.095 F ;
Gauge16
9: 110 Loc [ GF09 ]
;
Load strain gauge resistance values:
11: Bulk Load (P65)
1: 350 F ;
Gage01
2: 350 F ;
Gage02
3: 350 F ;
Gage03
4: 350 F ;
Gage04
5: 350 F ;
Gage05
6: 350 F ;
Gage06
7: 350 F ;
Gage07
8: 350 F ;
Gage08
9: 118 Loc [ G01Ohms ]
12: Bulk Load (P65)
1: 350 F ;
Gage09
2: 350 F ;
Gage10
3: 350 F ;
Gage11
4: 350 F ;
Gage12
5: 350 F ;
Gage13
6: 350 F ;
Gage14
28