Campbell Scientific 4WFBS120, 4WFBS350, 4WFBS1K 4 Wire Full Bridge Terminal Input Modules User Manual
Page 22
4WFBS120, 4WFBS350, 4WFBS1K 4 Wire Full Bridge Terminal Input Modules (TIM)
6: Z=F (P30)
;Load Gage Factor into input location
1: 2
F
;Enter the actual Gage Factor here
2: 6
Z Loc [ GF ]
7: Z=X/Y (P38)
;calculate multiplier to use with strain
1: 7
X Loc [ 4e6 ]
;calculation
2: 6
Y Loc [ GF ]
3: 8
Z Loc [ Mult ]
8: Beginning of Loop (P87)
;Loop through 5 times to obtain average
1: 0
Delay
;zero reading
2: 5
Loop
Count
9: Z=Z+1 (P32)
;Increment Counter used to determine
1: 5
Z Loc [ count ]
;when to output
10: Full Bridge (P6) ;Measure Strain Gage
1: 1
Reps
2: 2
± 15 mV Slow Range
3: 1
DIFF
Channel
4: 1
Excite all reps withExchan 1
5: 5000
mV
Excitation
6: 1
Loc [ mVperV ]
7: 1
Mult
8: 0
Offset
11: IF (X<=>F) (P89)
;Check for last pass through loop
1: 5
X Loc [ count ]
;to set output flag
2: 3
>=
3: 5
F
4: 10
Set
Output
Flag
High
12: Set Active Storage Area (P80)
;Direct averaged "zero" reading
1: 3
Input
Storage
;to input storage
2: 2
Array ID or Loc [ mVperV_0 ]
13: Average (P71)
1: 1
Reps
2: 1
Loc [ mVperV ]
14: If Flag/Port (P91)
;When average is calculated,
1: 10
Do if Output Flag is High (Flag 0)
;also send it to Final Storage
2: 10
Set
Output
Flag
High
15: Set Active Storage Area (P80)
;Direct Output to Final Storage
1: 1
Final
Storage
2: 11
Array
ID
;set Array ID = 11 for zero data
16: Real Time (P77)
1: 110
Day,Hour/Minute
17: Sample (P70)
1: 1
Reps
2: 2
Loc [ mVperV_0 ]
18: End (P95)
19: End (P95)
End Program
16