Campbell Scientific 4WFBS120, 4WFBS350, 4WFBS1K 4 Wire Full Bridge Terminal Input Modules User Manual
Page 18
4WFBS120, 4WFBS350, 4WFBS1K 4 Wire Full Bridge Terminal Input Modules (TIM)
Example Program 4.4. CR10X ¼ Bridge Strain with 1 rep and zero offset
;{CR10X}
*Table 1 Program
01: 1
Execution
Interval
(seconds)
1: If Flag/Port (P91)
;On the first execution (Flag 1 is low)
1: 21
Do if Flag 1 is Low
;or when user sets Flag 1 low
2: 1
Call
Subroutine
1
;call the zeroing subroutine
2: Full Bridge (P6)
;Measure the strain gage
1: 1
Reps
2: 22
± 7.5 mV 60 Hz Rejection Range
3: 1
DIFF
Channel
4: 1
Excite all reps withExchan 1
5: 2500
mV
Excitation
6: 1
Loc [ mVperV ]
7: 1
Mult
8: 0
Offset
3: X-Y (P35)
;Subtract zero reading from the
1: 1
X Loc [ mVperV ]
;measurement
2: 2
Y Loc [ mVperV_0 ]
3: 3
Z Loc [ Vr ]
4: X*F (P37)
;Change Vr from mV/V to V/V
1: 3
Loc [ Vr ]
2: 0.001
3: 3
Loc [ Vr ]
;The following instructions calculate microstrain
5: Z=X*F (P37)
1: 3
X Loc [ Vr ]
2: -2
F
3: 9
Z Loc [ 1_2Vr ]
6: Z=Z+1 (P32)
1: 9
Z Loc [ 1_2Vr ]
7: Z=X/Y (P38)
1: 3
X Loc [ Vr ]
2: 9
Y Loc [ 1_2Vr ]
3: 10
Loc [ Vr_1_2Vr ]
8: Z=X*Y (P36)
1: 10
X Loc [ Vr_1_2Vr ]
2: 8
Y Loc [ Mult ]
3: 4
Z Loc [ uStrain ]
; Output Section : This example outputs an average of the 1 second readings ;once per minute.
09: If time is (P92)
1: 0
Minutes (Seconds --) into a
2: 1
Interval (same units as above)
3: 10
Set
Output
Flag
High
10: Set Active Storage Area (P80)
1: 1
Final Storage Area 1
2: 1
Array
ID
;Set Array ID = 1 for measurement data
11: Real Time (P77)
1: 1110
Year,Day,Hour/Minute
12