Page 24

background image

24 | SAMLEX AMERICA INC.

The following spurious LeD indications may be seen at the Charge Controller and
may be disregarded:
Module(s) are exposed to Sunlight and battery has not been connected

No LeD indication

Module(s) are exposed to Sunlight, battery is Connected and then removed.

“PV” LeD (2):

Steady Green

“bATT” LeD (3):

Steady Green with red flickering

MAintenAnce

The following inspections and maintenance tasks are recommended for
optimum controller performance:

- Check that the controller is securely mounted in a clean and dry environment.
- Check that air flow and ventilation around the controller is not blocked. Clear all dirt or

fragments on the heat sink.

- Check all the exposed wires to make sure insulation is not damaged due to sunlight dam-

age, frictional, wear, dryness, insects or rats etc. Maintain or replace the wires, if necessary.

- Tighten all the terminals. Inspect for loose, broken, or burnt wire connections.
- Confirm that all the system components are grounded tightly and correctly.
- Confirm that all the terminals have no corrosion, insulation damage, discoloration due to

high temperature or burn damage.

- Tighten terminal screws to the suggested torque.
- Inspect for dirt, insects and corrosion and remove
- Check and confirm that lightning protection devices are good condition.

SeCtIOn 5 |

Protections, troubleshooting

& Maintenance