4 drawing – Matrix Orbital GTT70A User Manual
Page 17

13
Command Summary
2.4 Drawing
4.1 Set Background
Drawing Colour
Dec
Hex
ASCII
254 86
FE 56
þ V
R G B
R G B
R G B
2.0
Set the display colour when the Clear Screen command is sent. The default colour on startup is black.
R
Byte
Intensity of red, 0 to 255, limited to display metrics.
G
Byte
Intensity of green, 0 to 255, limited to display metrics.
B
Byte
Intensity of blue, 0 to 255, limited to display metrics.
4.2 Get Background
Drawing Colour
Dec
Hex
ASCII
254 87
FE 57
þ W
2.0
Read the background colour that is currently being used by all drawing commands.
Return Message
252 87 Length
R G B
R
Byte
Intensity of red, 0 to 255, limited to display metrics.
G
Byte
Intensity of green, 0 to 255, limited to display metrics.
B
Byte
Intensity of blue, 0 to 255, limited to display metrics.
4.3 Clear Screen
Dec
Hex
ASCII
254 88
FE 58
þ X
2.0
Clear the screen, and reset the coordinates for both continued line and font insertion commands to zero.
4.4 Scroll Screen
Dec
Hex
ASCII
254 89
FE 59
þ Y
X Y Width Height MoveX MoveY
X Y Width Height MoveX MoveY
X Y Width Height MoveX MoveY
2.0
Scroll the contents of a specified portion of the screen.
X
Signed Short
Leftmost coordinate of the scroll window.
Y
Signed Short
Topmost coordinate of the scroll window.
Width
Signed Short
Width of the scroll window.
Height
Signed Short
Height of the scroll window.
MoveX
Signed Short
Number of pixels to scroll horizontally.
MoveY
Signed Short
Number of pixels to scroll vertically.