Command Summary

10

2.4 Set Flow
Control Mode

Dec
Hex
ASCII

254 58

FE 3A

þ :

FlowControl
FlowControl
FlowControl

2.0

Toggle flow control between hardware and off settings. Default is RTSCTS. Serial command only.

FlowControl

Byte

Flow control setting, as per eFlowControl values.

Table 12: eFlowControl values

Value Description

0

Off

1

RTSCTS

2.5 Set I2C
Address

Dec
Hex
ASCII

254 247

FE F7

ю ч

I2Caddress
I2Caddress
I2Caddress

2.0

Immediately change the I2C write address. Only even values are permitted as the next odd address will become
the read address. Default 8 bit address is 80 decimal (0x50 hex). I2C command only.

I2Caddress

Byte

I2C write address, must be an even value.

2.6 Echo

Dec
Hex
ASCII

254 255

FE FF

ю я

Message
Message
Message

2.0

Echo a string that is sent to the display. This command can be used to test communication or indicate completion
of a successful power up when placed in the autoexec file.

Message

ASCII String

An arbitrary string that the module will return. Limited to 4KB in length.

Return Message

252 255 Length

ReturnMessage

ReturnMessage

ASCII String

The same arbitrary string originally sent.